      Ultrafast DNA Amplification Using Microchannel Flow-Through PCR Device.

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Polymerase chain reaction (PCR) is limited by the long reaction time for point-of-care. Currently, commercial benchtop rapid PCR requires 30−40 min, and this time is limited by the absence of rapid and stable heating and cooling platforms rather than the biochemical reaction kinetics. This study develops an ultrafast PCR (<3 min) platform using flow-through microchannel chips. An actin gene amplicon with a length of 151 base-pairs in the whole genome was used to verify the ultrafast PCR microfluidic chip. The results demonstrated that the channel of 56 μm height can provide fast heat conduction and the channel length should not be short. Under certain denaturation and annealing/extension times, a short channel design will cause the sample to drive slowly in the microchannel with insufficient pressure in the channel, causing the fluid to generate bubbles in the high-temperature zone and subsequently destabilizing the flow. The chips used in the experiment can complete 40 thermal cycles within 160 s through a design with the 56 µm channel height and with each thermal circle measuring 4 cm long. The calculation shows that the DNA extension speed is ~60 base-pairs/s, which is consistent with the theoretical speed of the Klen Taq extension used, and the detection limit can reach 67 copies. The heat transfer time of the reagent on this platform is very short. The simple chip design and fabrication are suitable for the development of commercial ultrafast PCR chips.

          Related collections

          Author and article information

          Journal
          Biosensors (Basel)
          Biosensors
          MDPI AG
          2079-6374
          2079-6374
          May 06 2022
          : 12
          : 5
          Affiliations
          [1 ] Graduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan 333, Taiwan.
          [2 ] Department of Laboratory Medicine, Chang Gung Memorial Hospital, Taoyuan 333, Taiwan.
          [3 ] Master and PhD Program in Biotechnology Industry, College of Medicine, Chang Gung University, Taoyuan 333, Taiwan.
          [4 ] Department of Medical Biotechnology and Laboratory Science, College of Medicine, Chang Gung University, Taoyuan 333, Taiwan.
          [5 ] Department of Thoracic Medicine, Chang Gung Memorial Hospital, Taoyuan 333, Taiwan.
          Article
          bios12050303
          10.3390/bios12050303
          9138433
          35624604
          a78dc831-a7e3-4608-a0fd-004fb22e855e
          History

          flow-through PCR,Klen Taq,ultrafast polymerase chain reaction,microchannel

          Comments

          Comment on this article