      Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed for HDR brachytherapy dosimetry. This includes work on the determination of dose rate fields around brachytherapy sources, the capability of treatment planning systems, the performance of treatment units and methods to verify dose delivery. This work highlights the determinants of accuracy in HDR dosimetry and treatment delivery and presents a selection of papers, focusing on articles from the last five years, to reflect active areas of research and development. Apart from Monte Carlo modelling of source dosimetry, there is no clear consensus on the optimum techniques to be used to assure dosimetric accuracy through all the processes involved in HDR brachytherapy treatment. With the exception of the ESTRO mailed dosimetry service, there is little dosimetric audit activity reported in the literature, when compared with external beam radiotherapy verification.

          Related collections

          Most cited references138

          • Record: found
          • Abstract: not found
          • Article: not found

          Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40.

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. American Association of Physicists in Medicine.

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Commissioning and quality assurance of treatment planning computers.

              The process of radiation therapy is complex and involves many steps. At each step, comprehensive quality assurance procedures are required to ensure the safe and accurate delivery of a prescribed radiation dose. This report deals with a comprehensive commissioning and ongoing quality assurance program specifically for treatment planning computers. Detailed guidelines are provided under the following topics: (a) computer program and system documentation and user training, (b) sources of uncertainties and suggested tolerances, (c) initial system checks, (d) repeated system checks, (e) quality assurance through manual procedures, and in vivo dosimetry, and (f) some additional considerations including administration and manpower requirements. In the context of commercial computerized treatment planning systems, uncertainty estimates and achievable criteria of acceptability are presented for: (a) external photon beams, (b) electron beams, (c) brachytherapy, and (d) treatment machine setting calculations. Although these criteria of acceptability appear large, they approach the limit achievable with most of today's treatment planning systems. However, developers of new or improved dose calculation algorithms should strive for the goal recommended by the International Commission of Radiation Units and Measurements of 2% in relative dose accuracy in low dose gradients or 2 mm spatial accuracy in regions with high dose gradients. For brachytherapy, the aim should be 3% accuracy in dose at distances of 0.5 cm or more at any point for any radiation source. Details are provided for initial commissioning tests and follow-up reproducibility tests. The final quality assurance for each patient is to perform an independent manual check of at least one point in the dose distributions, as well as the machine setting calculation. As a check of the overall treatment planning process, in vivo dosimetry should be performed on a select number of patients.
                Bookmark

                Author and article information

                Journal
                J Contemp Brachytherapy
                J Contemp Brachytherapy
                JCB
                Journal of Contemporary Brachytherapy
                Termedia Publishing House
                1689-832X
                2081-2841
                30 June 2012
                June 2012
                : 4
                : 2
                : 81-91
                Affiliations
                [1 ]Department of Physics, Faculty of Engineering and Physical Science, University of Surrey, United Kingdom
                [2 ]Medical Physics Department, Queen Alexandra Hospital, Portsmouth Hospitals NHS Trust, Portsmouth, United Kingdom
                [3 ]Medical Physics Department, Royal Surrey County Hospital NHS Foundation Trust, Guildford, United Kingdom
                Author notes
                Address for correspondence: Antony Palmer, Address for correspondence: Antony Palmer, MSc, Medical Physics Department (Radiotherapy Physics), F-Level, Queen Alexandra Hospital, Portsmouth, PO6 3LY, UK. e-mail: antony.palmer@ 123456porthosp.nhs.uk
                Article
                18873
                10.5114/jcb.2012.29364
                3552629
                23349649
                a4d75bd1-ca97-4d74-a21a-170db7149e5c
                Copyright © 2012 Termedia

                This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 18 March 2012
                : 14 April 2012
                : 05 May 2012
                Categories
                Review Article

                Oncology & Radiotherapy
                in vivo,accuracy,brachytherapy,treatment planning,high dose rate (hdr),dosimetry

                Comments

                Comment on this article