      Support-Material-Free Microfluidics on an Electrochemical Sensors Platform by Aerosol Jet Printing

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Printed electronics have led to new possibilities in the detection and quantification of a wide range of molecules important for medical, biotechnological, and environmental fields. The integration with microfluidics is often adopted to avoid hand-deposition of little volumes of reagents and samples on miniaturized electrodes that strongly depend on operator’s skills. Here we report design, fabrication and test of an easy-to-use electrochemical sensor platform with microfluidics entirely realized with Aerosol Jet Printing (AJP). We printed a six-electrochemical-sensors platform with AJP and we explored the possibility to aerosol jet print directly on it a microfluidic structure without any support material. Thus, the sacrificial material removal and/or the assembly with sensors steps are avoided. The repeatability observed when printing both conductive and ultraviolet (UV)-curable polymer inks can be supported from the values of relative standard deviation of maximum 5% for thickness and 9% for line width. We designed the whole microfluidic platform to make the sample deposition (20 μL) independent from the operator. To validate the platform, we quantified glucose at different concentrations using a standard enzyme-mediated procedure. Both mediator and enzyme were directly aerosol jet printed on working electrodes (WEs), thus the proposed platform is entirely fabricated by AJP and ready to use. The chronoamperometric tests show limit of detection (LOD) = 2.4 mM and sensitivity = 2.2 ± 0.08 µA/mM confirming the effectiveness of mediator and enzyme directly aerosol jet printed to provide sensing in a clinically relevant range (3–10 mM). The average relative standard inter-platform deviation is about 8%. AJP technique can be used for fabricating a ready-to-use microfluidic device that does not need further processing after fabrication, but is promptly available for electrochemical sample analysis.

          Related collections

          Most cited references47

          • Record: found
          • Abstract: found
          • Article: not found

          Enzyme immunoassay (EIA)/enzyme-linked immunosorbent assay (ELISA).

          This brief note addresses the historical background of the invention of the enzyme immunoassay (EIA) and enzyme-linked immunosorbent assay (ELISA). These assays were developed independently and simultaneously by the research group of Peter Perlmann and Eva Engvall at Stockholm University in Sweden and by the research group of Anton Schuurs and Bauke van Weemen in The Netherlands. Today, fully automated instruments in medical laboratories around the world use the immunoassay principle with an enzyme as the reporter label for routine measurements of innumerable analytes in patient samples. The impact of EIA/ELISA is reflected in the overwhelmingly large number of times it has appeared as a keyword in the literature since the 1970s. Clinicians and their patients, medical laboratories, in vitro diagnostics manufacturers, and worldwide healthcare systems owe much to these four inventors.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Electrochemical detection for paper-based microfluidics.

            We report the first demonstration of electrochemical detection for paper-based microfluidic devices. Photolithography was used to make microfluidic channels on filter paper, and screen-printing technology was used to fabricate electrodes on the paper-based microfluidic devices. Screen-printed electrodes on paper were characterized using cyclic voltammetry to demonstrate the basic electrochemical performance of the system. The utility of our devices was then demonstrated with the determination of glucose, lactate, and uric acid in biological samples using oxidase enzyme (glucose oxidase, lactate oxidase, and uricase, respectively) reactions. Oxidase enzyme reactions produce H2O2 while decomposing their respective substrates, and therefore a single electrode type is needed for detection of multiple species. Selectivity of the working electrode for H2O2 was improved using Prussian Blue as a redox mediator. The determination of glucose, lactate, and uric acid in control serum samples was performed using chronoamperometry at the optimal detection potential for H2O2 (0 V versus the on-chip Ag/AgCl reference electrode). Levels of glucose and lactate in control serum samples measured using the paper devices were 4.9 +/- 0.6 and 1.2 +/- 0.2 mM (level I control sample), and 16.3 +/- 0.7 and 3.2 +/- 0.3 mM (level II control sample), respectively, and were within error of the values measured using traditional tests. This study shows the successful integration of paper-based microfluidics and electrochemical detection as an easy-to-use, inexpensive, and portable alternative for point of care monitoring.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              SPR Biosensors: Historical Perspectives and Current Challenges

                Bookmark

                Author and article information

                Journal
                Sensors (Basel)
                Sensors (Basel)
                sensors
                Sensors (Basel, Switzerland)
                MDPI
                1424-8220
                18 April 2019
                April 2019
                : 19
                : 8
                : 1842
                Affiliations
                [1 ]Laboratory of Bio-Inspired & Graphene Nanomechanics, Department of Civil, Environmental and Mechanical Engineering, University of Trento, Via Mesiano, 77, 38123 Trento, Italy
                [2 ]Department of Information Engineering, University of Brescia, Via Branze 38, 25123 Brescia, Italy; e.cantu@ 123456unibs.it (E.C.); s.tonello@ 123456unibs.it (S.T.); emilio.sardini@ 123456unibs.it (E.S.)
                Author notes
                Author information
                https://orcid.org/0000-0002-7325-7988
                https://orcid.org/0000-0001-8629-7316
                https://orcid.org/0000-0001-6497-5876
                Article
                sensors-19-01842
                10.3390/s19081842
                6515300
                31003419
                9ed53d18-e471-4707-ad89-d23a31d99c7f
                © 2019 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).

                History
                : 28 March 2019
                : 16 April 2019
                Categories
                Article

                Biomedical engineering
                voltammetric sensors,aerosol jet printing,glucose sensing,3-d printing,support-material-free microfluidics

                Comments

                Comment on this article