      Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          An automated loop-centring program and a high-precision goniometer head used at the Swiss Light Source are described.

          Abstract

          Automatic loop centring has been developed as part of the automation process in crystallographic data collection at the Swiss Light Source. The procedure described here consists of an optional set-up part, in which the background images are taken, and the actual centring part. The algorithm uses boundary and centre-of-mass detection at two different microscope image magnifications. Micromounts can be handled as well. Centring of the loops can be achieved in 15–26 s, depending on their initial position, and as fast as manual centring. The alignment of the sample is carried out by means of a new flexural-hinge-based compact goniometer head. The device features an electromagnet for robotic wet mounting of samples. The circle of confusion was measured to be smaller than 1 µm (r.m.s.); its bidirectional backlash is below 2 µm.

          Related collections

          Author and article information

          Journal
          J Synchrotron Radiat
          J. Synchrotron Rad.
          Journal of Synchrotron Radiation
          International Union of Crystallography
          0909-0495
          1600-5775
          01 July 2011
          14 May 2011
          14 May 2011
          : 18
          : Pt 4 ( publisher-idID: s110400 )
          : 595-600
          Affiliations
          [a ]Paul Scherrer Institut, CH-5232 Villigen, Switzerland
          Author notes
          Correspondence e-mail: anuschka.pauluhn@ 123456psi.ch
          Article
          ms5033 JSYRES S0909049511011848
          10.1107/S0909049511011848
          3133520
          21685676
          99ee5b82-a2b2-44be-87ee-cd8471fd6538
          © Anuschka Pauluhn et al. 2011

          This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.

          History
          : 24 September 2010
          : 30 March 2011
          Categories
          Research Papers

          Radiology & Imaging
          beamline automation,sample centring,goniometer head
          Radiology & Imaging
          beamline automation, sample centring, goniometer head

          Comments

          Comment on this article