      Toric intraocular lenses for astigmatism correction after keratoplasty in phakic and pseudophakic eyes

      , ,
      Journal of Cataract and Refractive Surgery
      Ovid Technologies (Wolters Kluwer Health)

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references48

          • Record: found
          • Abstract: found
          • Article: not found

          Implantable collamer posterior chamber intraocular lenses: a review of potential complications.

          To review the peer-reviewed literature reporting postoperative complications of the most recent models of Visian Implantable Collamer posterior chamber intraocular lenses (ICL, STAAR Surgical Co). A literature search of the PubMed database was performed to identify all articles related to ICL complications. Articles were obtained and reviewed to identify those that reported complications using the latest ICL designs. Cataract was the major postoperative complication reported: 136 (5.2%) in 2592 eyes. Of those, 43.4% (n=59) were reported within 1 year, 15.4% (n=21) between 1 and 3 years, and 35.3% (n=48) ≥ 3 years after ICL implantation. Twenty-one (15.4%) cataracts were reported as surgically induced, 46 (33.8%) eyes had poor vault (<200 μm), and cataract surgery was carried out in 27.9% (n=38) of eyes. Early acute intraocular pressure increase was also reported to be relatively frequent, whereas acute pupillary block was less frequent and mostly resolved with additional iridotomies. A total of 42 ICLs were explanted due to cataract and IOP. Reported endothelial cell loss varied from 9.9% at 2 years to 3.7% 4 years postoperatively. This loss was reported to be more pronounced within the first 1 to 2 years, with stability or lower progression after that time. The majority of reported complications after ICL implantation are cataract formation. The improvements in lens geometry and more accurate nomograms applied to the selection of the lens to be implanted, in addition to the surgeon's learning curve, might be factors in the decreased occurrence of postoperative complications reported currently. Copyright 2011, SLACK Incorporated.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            A new system for grading recommendations in evidence based guidelines

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The AcrySof Toric intraocular lens in subjects with cataracts and corneal astigmatism: a randomized, subject-masked, parallel-group, 1-year study.

              To compare the AcrySof Toric intraocular lens (IOL) and an AcrySof spherical control IOL and to investigate rotational stability of the AcrySof Toric IOL (Alcon Laboratories, Inc., Fort Worth, TX) in subjects with cataracts and preexisting corneal astigmatism. Randomized, subject-masked, parallel-group, multicenter, 1-year study. We included 517 subjects (Toric IOL, n = 256; control IOL, n = 261). Unilateral implantation of an AcrySof Toric or AcrySof spherical control IOL (spherical powers, 12.00-25.00 diopters [D]; cylinder powers 1.50, 2.25, or 3.00 D for corneal astigmatism correction of 0.75 to < 1.50, ≥ 1.50 to <2.00, and ≥ 2.00 D with no upper limit, respectively). No limbal relaxing incisions were permitted. Visual acuity outcomes, IOL position, patient-reported spectacle use, and safety. One year postoperatively, best spectacle-corrected distance visual acuity of ≥ 20/20 was 77.7% (Toric IOL) versus 69.2% (control IOL). Uncorrected distance visual acuity of 20/20 or better was 40.7% (Toric IOL) versus 19.4% (control IOL; P<0.05). Mean absolute residual refractive cylinder was 0.59 D (Toric IOL) versus 1.22 D (control IOL; P<0.0001). Mean rotation was < 4° (range, 0°-20°) for the Toric IOL. Six-month spectacle freedom was 61.0% (Toric IOL) and 36.4% (control IOL; P < 0.0001). Complications in both groups were few and were as would be expected with cataract surgery. Favorable efficacy, rotational stability, distance vision spectacle freedom, and safety results support the use of the AcrySof Toric IOL for patients with cataracts and corneal astigmatism. Proprietary or commercial disclosure may be found after the references. Copyright © 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
                Bookmark

                Author and article information

                Journal
                Journal of Cataract and Refractive Surgery
                J Cataract Refract Surg
                Ovid Technologies (Wolters Kluwer Health)
                0886-3350
                1873-4502
                2022
                September 2022
                : 48
                : 9
                : 1078-1087
                Article
                10.1097/j.jcrs.0000000000000907
                99632b9e-34cd-478f-9733-58b9e4d4059f
                © 2022
                History

                Comments

                Comment on this article