      Plate selection for fixation of extra-articular distal humerus fractures: A biomechanical comparison of three different implants

      , , ,
      Injury
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Operative fixation of extra-articular distal humerus using a single posterolateral column plate has been described but the biomechanical properties or limits of this technique is undefined. The purpose of this study was to evaluate the mechanical properties of distal humerus fracture fixation using three standard fixation constructs. Two equal groups were created from forty sawbones humeri. Osteotomies were created at 80mm or 50mm from the tip of the trochlea. In the proximal osteotomy group, sawbones were fixed with an 8-hole 3.5mm LCP or with a 6-hole posterolateral plate. In the distal group, sawbones were fixed with 9-hole medial and lateral 3.5mm distal humerus plates and ten sawbones were fixed with a 6-hole posterolateral plate. Biomechanical testing was performed using a servohydraulic testing machine. Testing in extension as well as internal and external rotation was performed. Destructive testing was also performed with failure being defined as hardware pullout, sawbone failure or cortical contact at the osteotomy. In the proximal osteotomy group, the average bending stiffness and torsional stiffness was significantly greater with the posterolateral plate than with the 3.5mm LCP. In the distal osteotomy group, the average bending stiffness and torsional stiffness was significantly greater with the posterolateral plate than the 3.5mm LCP. In extension testing, the yield strength was significantly greater with the posterolateral plate in the proximal osteotomy specimens, and the dual plating construct in the distal osteotomy specimens. The yield strength of specimens in axial torsion was significantly greater with the posterolateral plate in the proximal osteotomy specimens, and the dual plating construct in the distal osteotomy specimens. Limited biomechanical data to support the use of a pre-contoured posterolateral distal humerus LCP for fixation of extra-articular distal humerus exists. We have found that this implant provided significantly greater bending stiffness, torsional stiffness, and yield strength than a single 3.5mm LCP plate for osteotomies created 80mm from the trochlea. At the more distal osteotomy, dual plating was biomechanically superior. Our results suggest that single posterolateral column fixation of extra-articular humerus fractures is appropriate for more proximal fractures but that dual plate fixation is superior for more distal fractures.

          Related collections

          Author and article information

          Journal
          Injury
          Injury
          Elsevier BV
          00201383
          December 2014
          December 2014
          : 45
          : 12
          : 2040-2044
          Article
          10.1016/j.injury.2014.08.036
          25249244
          94b6408d-ef90-43f9-8077-b6e5c0d09bb0
          © 2014

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article