0
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Novel applications of nonwood cellulose for blood typing assays

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references21

          • Record: found
          • Abstract: found
          • Article: not found

          Simple telemedicine for developing regions: camera phones and paper-based microfluidic devices for real-time, off-site diagnosis.

          This article describes a prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site. The system uses paper-based microfluidic devices for running multiple assays simultaneously, camera phones or portable scanners for digitizing the intensity of color associated with each colorimetric assay, and established communications infrastructure for transferring the digital information from the assay site to an off-site laboratory for analysis by a trained medical professional; the diagnosis then can be returned directly to the healthcare provider in the field. The microfluidic devices were fabricated in paper using photolithography and were functionalized with reagents for colorimetric assays. The results of the assays were quantified by comparing the intensities of the color developed in each assay with those of calibration curves. An example of this system quantified clinically relevant concentrations of glucose and protein in artificial urine. The combination of patterned paper, a portable method for obtaining digital images, and a method for exchanging results of the assays with off-site diagnosticians offers new opportunities for inexpensive monitoring of health, especially in situations that require physicians to travel to patients (e.g., in the developing world, in emergency management, and during field operations by the military) to obtain diagnostic information that might be obtained more effectively by less valuable personnel.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            FLASH: a rapid method for prototyping paper-based microfluidic devices.

            This article describes FLASH (Fast Lithographic Activation of Sheets), a rapid method for laboratory prototyping of microfluidic devices in paper. Paper-based microfluidic devices are emerging as a new technology for applications in diagnostics for the developing world, where low cost and simplicity are essential. FLASH is based on photolithography, but requires only a UV lamp and a hotplate; no clean-room or special facilities are required (FLASH patterning can even be performed in sunlight if a UV lamp and hotplate are unavailable). The method provides channels in paper with dimensions as small as 200 microm in width and 70 microm in height; the height is defined by the thickness of the paper. Photomasks for patterning paper-based microfluidic devices can be printed using an ink-jet printer or photocopier, or drawn by hand using a waterproof black pen. FLASH provides a straightforward method for prototyping paper-based microfluidic devices in regions where the technological support for conventional photolithography is not available.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Low-cost printing of poly(dimethylsiloxane) barriers to define microchannels in paper.

              This paper describes the use of a modified x,y-plotter to generate hydrophilic channels by printing a solution of hydrophobic polymer (pol(dimethylsiloxane; PDMS) dissolved in hexanes onto filter paper. The PDMS penetrates the depth of the paper and forms a hydrophobic wall that aqueous solutions cannot cross. The minimum size of printed features is approximately 1 mm; this resolution is adequate for the rapid prototyping of hand-held, visually read, diagnostic assays (and other microfluidic systems) based on paper. After curing the printed PDMS, the paper-based devices can be bent or folded to generate three-dimensional systems of channels. Capillary action pulls aqueous samples into the paper channels. Colorimetric assays for the presence of glucose and protein are demonstrated in the printed devices; spots of Bromothymol Blue distinguished samples with slightly basic pH (8.0) from samples with slightly acidic pH (6.5). The work also describes using printed devices that can be loaded using multipipets and printed flexible, foldable channels in paper over areas larger than 100 cm2.
                Bookmark

                Author and article information

                Journal
                Journal of Biomedical Materials Research Part B: Applied Biomaterials
                J. Biomed. Mater. Res.
                Wiley
                1552-4973
                1552-4981
                October 03 2018
                July 2019
                October 03 2018
                July 2019
                : 107
                : 5
                : 1533-1541
                Affiliations
                [1 ]Mechanical Engineering Department, MicroTech LabTechnical University of Catalonia Terrassa Spain
                [2 ]CELBIOTECH Paper Engineering Research GroupTechnical University of Catalonia Terrassa Spain
                Article
                10.1002/jbm.b.34245
                93a921e4-cbe7-405f-9d55-2b6f32757ca5
                © 2019

                http://onlinelibrary.wiley.com/termsAndConditions#vor

                http://doi.wiley.com/10.1002/tdm_license_1.1

                History

                Comments

                Comment on this article