      Significance of implant design on the efficacy of different peri-implantitis decontamination protocols

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references26

          • Record: found
          • Abstract: not found
          • Article: not found

          Peri-implant diseases and conditions: Consensus report of workgroup 4 of the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Peri-implant health and disease. A systematic review of current epidemiology

            To develop preventive strategies addressing peri-implant diseases, a thorough understanding of the epidemiology is required.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The effect of thread pattern upon implant osseointegration.

              Implant design features such as macro- and micro-design may influence overall implant success. Limited information is currently available. Therefore, it is the purpose of this paper to examine these factors such as thread pitch, thread geometry, helix angle, thread depth and width as well as implant crestal module may affect implant stability. A literature search was conducted using MEDLINE to identify studies, from simulated laboratory models, animal, to human, related to this topic using the keywords of implant thread, implant macrodesign, thread pitch, thread geometry, helix angle, thread depth, thread width and implant crestal module. The results showed how thread geometry affects the distribution of stress forces around the implant. A decreased thread pitch may positively influence implant stability. Excess helix angles in spite of a faster insertion may jeopardize the ability of implants to sustain axial load. Deeper threads seem to have an important effect on the stabilization in poorer bone quality situations. The addition of threads or microthreads up to the crestal module of an implant might provide a potential positive contribution on bone-to to-implant contact as well as on the preservation of marginal bone; nonetheless this remains to be determined. Appraising the current literature on this subject and combining existing data to verify the presence of any association between the selected characteristics may be critical in the achievement of overall implant success.
                Bookmark

                Author and article information

                Contributors
                Journal
                Clinical Oral Investigations
                Clin Oral Invest
                Springer Science and Business Media LLC
                1432-6981
                1436-3771
                June 2021
                November 10 2020
                June 2021
                : 25
                : 6
                : 3589-3597
                Article
                10.1007/s00784-020-03681-y
                33170374
                8f399b53-3e69-4211-acf9-f95bc844e7dc
                © 2021

                https://www.springer.com/tdm

                https://www.springer.com/tdm

                History

                Comments

                Comment on this article