13
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Safety, efficacy, and quality control of a photoelectric dye-based retinal prosthesis (Okayama University-type retinal prosthesis) as a medical device.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Patients with retinitis pigmentosa lose photoreceptor cells as a result of genetic abnormalities and hence become blind. Neurons such as bipolar cells and ganglion cells remain alive even in the retina of these patients, and ganglion cells send axons to the brain as the optic nerve. The basic concept of retinal prostheses is to replace dead photoreceptor cells with artificial devices to stimulate the remaining neurons with electric currents or potentials. Photodiode arrays and digital camera-type electrode arrays are the two main approaches for retinal prostheses to stimulate retinal neurons, but these arrays have the problems of poor biocompatibility, low sensitivity, and low output of electric currents, and hence have a requirement for external electric sources (batteries). To overcome these problems, we are developing photoelectric dye-based retinal prostheses that absorb light and convert photon energy to generate electric potentials. The prototype, using a photoelectric dye-coupled polyethylene film, could induce intracellular calcium elevation in photoreceptor-lacking embryonic retinal tissues and cultured retinal neurons. The subretinal implantation of the prototype in the eyes of Royal College of Surgeons (RCS) rats led to vision recovery as proved by a behavior test. The photoelectric dye that was chosen for the prototype did not exhibit any cytotoxicity. The surface potentials of the photoelectric dye-coupled film showed a rapid on-and-off response to illumination with a threshold for light intensity as measured by a Kelvin probe system. Photoelectric dye-based retinal prostheses are thin and soft, and therefore, a sheet of the film of large size, corresponding to a large visual field, could be inserted into the vitreous and then to the subretinal space through a small opening by rolling up the film. Clinical studies of photoelectric dye-based retinal prostheses in patients with retinitis pigmentosa who lose sight will be planned after the manufacturing control and the quality control had been established for the medical device.

          Related collections

          Author and article information

          Journal
          J Artif Organs
          Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs
          Springer Nature
          1619-0904
          1434-7229
          2009
          : 12
          : 4
          Affiliations
          [1 ] Department of Ophthalmology, Okayama University Medical School and Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Okayama, Japan. matsuot@cc.okayama-u.ac.jp
          Article
          10.1007/s10047-009-0471-6
          20035394
          8ecfb703-78a3-4ff1-8e80-746b6c581b3c
          History

          Comments

          Comment on this article