      A narrative review on techniques of iris replication in an ocular prosthesis

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The disfigurement associated due to the loss of an eye can cause a significant physical and psychological disturbance. Psychological distress among such unfortunate patients can be reduced by providing an artificial eye. Rehabilitating such patients with an ocular defects is the most challenging task for a prosthodontist. The custom-made ocular prostheses are preferred over the prefabricated stock eye shells as it provides intimate contact with the tissue bed, enabling an ideal fit. For an esthetic ocular prosthesis, the precise positioning of an iris is a primary requirement to avoid the squint eye appearance. Various case reports are documented in the literature for centralizing the iris in the prosthetic eye. This review article explores the established methods and techniques for positioning the iris in a custom-made ocular prosthesis.

          Related collections

          Most cited references26

          • Record: found
          • Abstract: found
          • Article: not found

          A simple method of positioning the iris disk on a custom-made ocular prosthesis. A clinical report.

          We report two cases of ocular prosthesis fabrication that make use of a transparent graph grid for positioning the iris disk. The custom-made ocular prostheses achieved intimate contact with the tissue bed enabling ideal fit. As asymmetry may result in a squint-eyed appearance, proper positioning of the iris disk in the scleral wax pattern is vital to fabricating the custom-made artificial eye. The position of the iris disk in the custom-made ocular prosthesis was in symmetry with that of the natural eye, restoring esthetics of the patient.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Assessment of the Change in Color of Maxillofacial Silicone after Curing Using a Mobile Phone Colorimeter Application.

            To evaluate the change in color of the maxillofacial silicone after curing using a mobile phone colorimeter application.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Iris Positioning Using a Grid Attached to a Spring Bow for a Custom Ocular Prosthesis

              Eyes are among the first features of the face to be noticed. Loss of an eye due to congenital, traumatic or pathologic aetiologies causes disfigurement and loss of sensory feedback. It leaves a psychological impact on the patient, thus prosthesis should be provided at the earliest to raise the spirits of the afflicted. Iris positioning is one of the important steps in fabricating customized ocular prosthesis. In facial asymmetry cases, comparison of both irises together can be a major disadvantage. This case report illustrates the use of a unique customized frame spring bow assembly to position the iris disk using the established parallelism between inter pupillary line to the horizontal plane.
                Bookmark

                Author and article information

                Journal
                J Indian Prosthodont Soc
                J Indian Prosthodont Soc
                JIPS
                The Journal of the Indian Prosthodontic Society
                Wolters Kluwer - Medknow (India )
                0972-4052
                1998-4057
                Jan-Mar 2023
                29 December 2022
                : 23
                : 1
                : 4-11
                Affiliations
                [1]Department of Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, Maharashtra, India
                [1 ]Trauma Care Centre, Government Medical College and Hospital, Nagpur, Maharashtra, India
                Author notes
                Address for correspondence: Dr. Sharayu Vinod Nimonkar, Plot No 97, Hindusthan Colony, Wardha Road, Nagpur, Maharashtra, India. E-mail: snimonkar@ 123456gmail.com
                Article
                JIPS-23-4
                10.4103/jips.jips_252_22
                10088441
                36588369
                8e2e9009-c1b7-4a92-b24a-980c0acab272
                Copyright: © 2022 The Journal of Indian Prosthodontic Society

                This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

                History
                : 18 May 2022
                : 13 October 2022
                : 22 October 2022
                Categories
                Review

                customized scale,facial measurements,graph grid,iris positioning,ocular prosthesis,prosthetic eye

                Comments

                Comment on this article