          Abstract

          Background

          The majority of dental professionals currently recognize lithium disilicate E-max ceramic veneers as a the most widely used, conservative, and effective cosmetic materials in dentistry. This study aimed to compare the degree of surface changes – roughness (Ra), depth (Rz), and mean color changes (Δ E 00 ) – of computer-aided design-computer-aided manufactured (CAD/CAM) ceramic veneers materials of varying thicknesses caused by staining by green tea, coffee, and Coca-Cola using digital spectrophotometer.

          Material/Methods

          This study was conducted at King Khalid University, College of Dentistry. Lithium disilicate glass ceramic (LDGC) material was used to create 60 rectangular slices using the CAD/CAM system. The material thickness and the type of beverage were measured. The specimens were immersed in beverages according to the manufacturer’s instructions. Specimen description and tomography were completed with a 3D noncontact surface metrology using interferometry. The “VITA Easy-Shade” spectrophotometer was used to measure Δ E 00 . It was recorded after 2 weeks for different material thicknesses after immersing samples in green tea, coffee, and Coca-Cola staining materials.

          Results

          Significant changes in ceramic thickness were found in Ra and Rz of 0.07 and 1.00 mm after 14 days of staining. Coca-Cola showed a significant difference in Ra and Rz with 1.00 mm thickness measurement compared to the 0.07 mm group with ≤ of 0.05, which was considered statistically significant. Highest Δ E 00 were recorded among samples stained by Coca-Cola, followed by coffee, for both thicknesses.

          Conclusions

          Those findings support previous studies using spectrophotometric analysis of staining of CAD-CAM ceramic veneers that Coca-Cola followed by coffee resulted in the greatest color Δ E 00 change.

          Related collections

          Most cited references65

          • Record: found
          • Abstract: found
          • Article: not found

          The use of CAD/CAM in dentistry.

          Computer-aided design (CAD) and computer-aided manufacturing (CAM) have become an increasingly popular part of dentistry over the past 25 years. The technology, which is used in both the dental laboratory and the dental office, can be applied to inlays, onlays, veneers, crowns, fixed partial dentures, implant abutments, and even full-mouth reconstruction. This article discusses the history of CAD/CAM in dentistry and gives an overview of how it works. It also provides information on the advantages and disadvantages, describes the main products available, discusses how to incorporate the new technology into your practice, and addresses future applications. Copyright © 2011 Elsevier Inc. All rights reserved.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Color stainability of CAD/CAM and nanocomposite resin materials.

            The color stainability of recently introduced computer-assisted design/computer-assisted manufacturing (CAD/CAM) hybrid ceramic and resin nanoceramic is unknown.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Assessment of perceptibility and acceptability of color difference of denture teeth.

              To assess the color difference values that represent the perceptibility and acceptability thresholds of denture teeth. Eighteen interchangeable right upper central incisors denture teeth were selected to have color difference values from representative left upper central incisor denture tooth in a range of 0.4-11.4 ΔE* units measured with a spectrophotometer (CM 2600d, Minolta Konica, Japan). These teeth were placed in an artificial dental arch in a phantom head. Under controlled conditions, a total of 80 observers divided into 4 groups (technicians, nurses, dentists and researchers) were asked to report the perceptibility and acceptability of each of the color difference values. The findings was then analysed using logistic regression for determining the perceptible and acceptable thresholds of dental color differences. The determined color difference values at which 50% of all observers could detect a color difference (50:50 probability) was 1.9 ΔE* units with a 95% confidence interval and ranged from 1.7 ΔE* units to 2.1 ΔE* units. The determined color difference value at which 50% of all observes preferred to replace the tooth because of unacceptable color difference (50:50 probability) was 4.2 with a 95% confidence interval that ranged from 3.9 ΔE* units to 4.7 ΔE* units. Within the limitation of this study, the following conclusions were made: 1. The mean color perceptibility threshold was significantly lower than the mean color acceptability threshold. 2. Significant differences between different observers groups were noticed in determination of perceptibility and acceptability of color differences. The technicians groups displayed lower perceptibility and acceptability limits than the dental nurses and non-dental observers. When shade matching artificial denture teeth to natural teeth, 50:50 perceptibility (1.9 ΔE* units) and acceptability (4.2 ΔE* units) thresholds are used to compare color difference values. The technicians group displayed lower perceptibility and acceptability limits than other observers. Copyright © 2012 Elsevier Ltd. All rights reserved.
                Bookmark

                Author and article information

                Journal
                Med Sci Monit
                Med Sci Monit
                Medical Science Monitor
                Medical Science Monitor : International Medical Journal of Experimental and Clinical Research
                International Scientific Literature, Inc.
                1234-1010
                1643-3750
                2023
                07 February 2023
                17 January 2023
                : 29
                : e939341-1-e939341-11
                Affiliations
                Department of Restorative Dental Science, College of Dentistry, King Khalid University, Abha, Saudi Arabia
                Author notes
                Corresponding Author: Mohammed H.D. Al Wadei, e-mail: moalwadai@ 123456kku.edu.sa
                [A]

                Study Design

                [B]

                Data Collection

                [C]

                Statistical Analysis

                [D]

                Data Interpretation

                [E]

                Manuscript Preparation

                [F]

                Literature Search

                [G]

                Funds Collection

                Author information
                https://orcid.org/0000-0001-9201-5696
                Article
                939341
                10.12659/MSM.939341
                9920997
                36747464
                8c9f63c7-44ef-48c1-88a4-a40dcd2d12aa
                © Med Sci Monit, 2023

                This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International ( CC BY-NC-ND 4.0)

                History
                : 26 December 2022
                : 11 January 2023
                Categories
                Database Analysis

                coffee,color perception,dental materials,vita veneering ceramic d

                Comments

                Comment on this article