      Micro-mechanical damage of needle puncture on bovine annulus fibrosus fibrils studied using polarization-resolved Second Harmonic Generation(P-SHG) microscopy.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Needle injection has been widely used in spinal therapeutic or diagnostic processes, such as discography. The use of needles has been suspected in causing mild disc degeneration which can lead to long-term back pain. However, the localised microscopic damage caused by needles has not been well studied. The local progressive damage on a microscopic level caused by needle punctures on the surface of bovine annulus fibrosus was investigated. Four different sizes of needle were used for the puncture and twenty-nine bovine intervertebral discs were studied. Polarization-resolved second harmonic generation and fluorescent microscopy were used to study the local microscopic structural changes in collagen and cell nuclei due to needle damage. Repeated 70 cyclic loadings at ±5% of axial strain were applied after the needle puncture in order to assess progressive damage caused by the needle. Puncture damage on annulus fibrosus were observed either collagen fibre bundles being pushed aside, being cut through or combination of both with part being lift or pushed in. The progressive damage was found less relevant to the needle size and more progressive damage was only observed using the larger needle. Two distinct populations of collagen, in which one was relatively more organised than the other population, were observed especially after the puncture from skewed distribution of polarization-SHG analysis. Cell shape was found rounder near the puncture site where collagen fibres were damaged.

          Related collections

          Author and article information

          Journal
          J Mech Behav Biomed Mater
          Journal of the mechanical behavior of biomedical materials
          Elsevier BV
          1878-0180
          1878-0180
          June 2021
          : 118
          Affiliations
          [1 ] College of Engineering, Mathematics & Physical Sciences, Physics Building, Stocker Road, Exeter, EX4 4QL, UK. Electronic address: j.wang3@exeter.ac.uk.
          [2 ] College of Engineering, Mathematics & Physical Sciences, Physics Building, Stocker Road, Exeter, EX4 4QL, UK.
          [3 ] Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, F-13013, Marseille, France.
          [4 ] Arts et Métiers Institute of Technology, Université Sorbonne Paris Nord, IBHGC - Institut de Biomécanique Humaine Georges Charpak, HESAM Université, F-75013, Paris.
          Article
          S1751-6161(21)00145-4
          10.1016/j.jmbbm.2021.104458
          33761373
          8c95ada3-4e1b-4a9b-8644-7d8756fb1729
          History

          Needle puncture,Biomechanics,Bovine intervertebral disc,Disc degeneration,Intervertebral disc degeneration,Multiphoton microscopy,Second harmonic generation

          Comments

          Comment on this article