          Objective: Er:YAG laser-activated irrigation (LAI) is an effective method of root canal cleaning, but irrigant extrusion from the apical foramen has been a concern. We aimed to analyze the effects of pulse energy, pulse frequency, and laser tip diameter on intracanal vapor bubble kinetics and periapical pressure generation during LAI with Er:YAG laser. Background: Irrigant vapor bubble kinetics are one of indices of root canal cleaning efficacy. However, few studies have compared laser pulse conditions to vapor bubble kinetics, in relation to periapical pressure. Methods: A plastic root canal model (apical diameter 0.50 mm, 6% taper, 20 mm long) was filled with distilled water, and LAI with Er:YAG laser (Erwin AdvErl Unit; 30, 50, or 70 mJ; 10, or 20 pulses per second; laser tip R200T or R600T) was performed with the end of the tip fixed at 15 mm from the root apex. The number, maximum diameter, and velocity of vapor bubbles were analyzed by high-speed video imaging. Pressure generated outside the apical foramen was measured with a pressure sensor. Results: Vapor bubble count and maximum diameter increased significantly with pulse energy, pulse frequency, and tip diameter. Vapor bubble velocity increased significantly with pulse frequency, but not with pulse energy or tip diameter. Periapical pressure increased significantly with pulse energy, pulse frequency, and tip diameter. Conclusions: The pulse frequency was the single factor that significantly affected all the examined parameters (the number, diameter, and velocity) of vapor bubble kinetics together with the periapical pressure.

          Related collections

          Author and article information

          Journal
          Photobiomodul Photomed Laser Surg
          Photobiomodulation, photomedicine, and laser surgery
          Mary Ann Liebert Inc
          2578-5478
          2578-5478
          Jul 2020
          : 38
          : 7
          Affiliations
          [1 ] Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
          Article
          10.1089/photob.2019.4739
          32364877
          8a3cb0e5-3c47-4ce4-9372-3290b98bf361
          History

          Er:YAG laser,laser-activated irrigation,vapor bubble velocity,vapor bubble maximum diameter,vapor bubble count

          Comments

          Comment on this article