2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Effectiveness and efficiency of a dedicated bimodal fitting formula

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The population of unilateral cochlear implant (CI) users with aidable residual hearing in the contralateral ear is continuously growing. Aiding the contralateral ear with a hearing aid has been shown to provide substantial benefit regarding speech intelligibility in quiet and in noise, sound quality, localization ability and listening effort. In this study, a dedicated hearing aid with the accompanying fitting prescription, tailored to the needs of bimodal listeners was evaluated in nine bimodal CI users. Speech intelligibility scores in noise revealed on-par performance of the dedicated bimodal fitting compared to the clinical standard prescription. 78% of the bimodal CI users preferred the dedicated bimodal fitting over the clinical standard. The minimal subject-specific finetuning effort required during the dedicated bimodal fitting process emphasizes the clinical efficiency.

          Related collections

          Most cited references16

          • Record: found
          • Abstract: found
          • Article: not found

          Development and analysis of an International Speech Test Signal (ISTS).

          For analysing the processing of speech by a hearing instrument, a standard test signal is necessary which allows for reproducible measurement conditions, and which features as many of the most relevant properties of natural speech as possible, e.g. the average speech spectrum, the modulation spectrum, the variation of the fundamental frequency together with its appropriate harmonics, and the comodulation in different frequency bands. Existing artificial signals do not adequately fulfill these requirements. Moreover, recordings from natural speakers represent only one language and are therefore not internationally acceptable. For this reason, an International Speech Test Signal (ISTS) was developed. It is based on natural recordings but is largely non-intelligible because of segmentation and remixing. When using the signal for hearing aid measurements, the gain of a device can be described at different percentiles of the speech level distribution. The primary intention is to include this test signal with a new measurement method for a new hearing aid standard (IEC 60118-15).
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            The NAL-NL2 Prescription Procedure

            NAL-NL2 is the second generation of prescription procedures from The National Acoustic Laboratories (NAL) for fitting wide dynamic range compression (WDRC) instruments. Like its predecessor NAL-NL1 (Dillon, 1999), NAL-NL2 aims at making speech intelligible and overall loudness comfortable. This aim is mainly driven by a belief that these factors are most important for hearing aid users, but is also driven by the fact that less information is available about how to adjust gain to optimise other parameters that affect prescription such as localisation, tonal quality, detection of environmental sounds, and naturalness. In both formulas, the objective is achieved by combining a speech intelligibility model and a loudness model in an adaptive computer-controlled optimisation process. Adjustments have further been made to the theoretical component of NAL-NL2 that are directed by empirical data collected during the past decade with NAL-NL1. In this paper, the data underlying NAL-NL2 and the derivation procedure are presented, and the main differences from NAL-NL1 are outlined. The optimisation procedure A schematic overview of the adaptive optimisation procedure is shown in Figure 1. The two inputs to the process are the input speech spectrum and level, and the audiogram for which a prescription is required. The output is the prescription expressed as a gain-frequency response. The two input parameters are entered into two feedback loops, which operate in tandem to optimise the gain-frequency response. One loop uses an intelligibility model to find the gain-frequency response that maximises speech intelligibility. If left unchecked, this loop would produce the same output level irrespective of the input level of speech, a result that would not give the hearing aid wearer an acceptable representation of the auditory world. The second loop therefore uses a loudness model (Moore & Glasberg, 1997; 2004) to calculate the loudness that would be perceived by the hearing-impaired person with the selected gain-frequency response. The calculated loudness is compared to the loudness that would be perceived by a normal-hearing person listening to the same input speech spectrum and level. If loudness calculated for the audiogram exceeds the normal-hearing loudness, the overall gain is decreased. The adaptive process was used to derive the optimal gain-frequency responses for 240 audiograms, covering a wide range of severity and slopes, each at seven speech input levels from 40 to 100 dB SPL. Using a neural network, the optimised gain values from all the audiograms and all the input levels were drawn together into a single composite prescription formula. The theoretical derivation of NAL-NL2 differed from that of NAL-NL1 on two points. First, the intelligibility model, which is a revised version of the speech intelligibility index (SII) formula (ANSI, 1997), was updated. The difference between the original SII formula and the speech intelligibility model used to derive NAL-NL1 and NAL-NL2 is in the audibility factor. In the original SII formula the audibility factor assumes that, irrespective of the degree of hearing loss, speech is fully understood when all speech components are audible. In the speech intelligibility model used in the optimisation procedure, an effective audibility factor has been introduced, which takes into account that as the hearing loss gets more severe, less information is extracted from the speech signal, even when it is audible above threshold. The effective audibility factor was based on data collected at NAL prior to deriving NAL-NL1 (Ching, et al., 1998). The further revision made to the speech intelligibility model before deriving NAL-NL2 was based on more extensive data collected on 70 adults on how much information people with hearing loss can extract from speech once it has been made audible. Data were collected both in quiet and in noise and resulted in a new effective audibility factor. Second, constraints to the selected gain were applied such that no compression was introduced for speech presented below 50 dB SPL, and no gain was prescribed at frequencies below 50 Hz and above 16 kHz. The latter constraints ensured a smoother gain-frequency response between the two anchor points. These changes have resulted in NAL-NL2 prescribing a different gain-frequency response slope to NAL-NL1. Generally, NAL-NL2 prescribes relatively more gain across low and high frequencies and less gain across mid frequencies than NAL-NL1, see Figure 2. In the speech intelligibility model, an importance function is used to ensure that sufficient gain is applied at the frequencies that are most important for speech understanding. Low frequencies are more important in tonal languages, which are most common across Asia and Africa, than in non-tonal languages. Therefore, when deriving NAL-NL2, the optimisation procedure was run twice using different importance functions in the speech intelligibility model to derive gain for the two types of languages. As a result there are two versions of NAL-NL2, and slightly more gain is prescribed across the low frequencies for tonal than for non-tonal languages. Adjustments to optimised data Before deriving the theoretical NAL-NL2 formula, constraints were further applied to the optimised gain values such that the compression ratio for a given frequency and degree of hearing loss could not exceed a maximum value, selected to avoid any detrimental effect on speech understanding. Data have suggested that hearing aid users with severe or profound hearing loss prefer lower compression ratios than prescribed by NAL-NL1, when fitted with fast-acting compression (Keidser, et al., 2007). As demonstrated in Figure 3, the study participants selected lower compression ratios across the low than high frequencies, presumably to obtain a better preservation of both the speech envelope and the prosodic cues. There is, however, no reasons to believe that this population could not benefit from higher compression ratios, which would provide audibility of a wider range of input levels, when listening with slow-acting compression. Consequently, two sets of limits were applied to the optimised gain data, and as a result NAL-NL1 will prescribe higher compression ratios to people with a severe or profound hearing loss if they are fitted with slow-acting compression than when fitted with fast-acting compression, see Figure 4. Compression speed has no real effect on the compression ratio prescribed to hearing aid users with milder hearing loss. Adjustments to overall gain Many experiments in which NAL-NL1 has been used as baseline response have provided empirical data that suggest how much gain hearing aid users with different profiles prefer. For example, the realear insertion gain measurements of the fine-tuned, or preferred, response for a 65 dB input level by 187 adults who have participated in various research projects were analysed. The analysis revealed that female hearing aid users, irrespective of degree of hearing loss and experience with amplification preferred less gain (2 dB, on average) than male hearing aid users (Keidser & Dillon, 2006). The difference in preferred gain was statistically significant (P<0.05). Consequently, NAL-NL2 prescribes gender specific gain. The same data set showed that when the hearing loss was mild there was no difference in overall gain preferred by new and experienced hearing aid users. However, when the hearing loss became moderate, new hearing aid users preferred significantly less gain than experienced hearing aid users. In fact, progressively less gain was preferred by new users as the degree of hearing loss increased (Keidser, et al., 2008). Data collected for a small sample suggested that, on average, new hearing aid users with moderate hearing loss adapted to gain levels preferred by experienced hearing aid users with a similar degree of hearing loss over a period of about two years. On this background, NAL-NL2 recommends gain adaptation for new hearing aid users with more than a mild hearing loss. From the same data set, it could also be concluded that adults with mild and moderate hearing loss generally preferred less overall gain (3 dB, on average) than prescribed by NAL-NL1 for a 65 dB SPL input. At least two studies have further demonstrated that hearing aid users with mild or moderate hearing loss preferred a relatively higher gain reduction for higher input levels (80 dB SPL) but a relatively smaller gain reduction for lower input levels (50 dB SPL), which means that the adults preferred a slightly higher compression ratio than prescribed by NAL-NL1 (Smeds, et al., 2006; Zakis, et al., 2007), see Figure 5. In contrast, a study on children suggested that the younger population preferred higher gain than adults (Scollie, et al., 2010). An increase in gain is more likely to lead to greater speech intelligibility at low input levels where speech is most limited by audibility, and is less likely to cause noise-induced hearing loss for low input levels than for high input levels. Therefore, gain is for children increased for low input levels with a progressive decrease in increased gain with increased input level (Figure 5). That is, NAL-NL2 also prescribes a relatively higher compression ratio for children with mild or moderate hearing loss than do NAL-NL1. Conclusions NAL-NL2 is a revised version of NAL-NL1. The revisions are based on extensive empirical data. In comparison to NAL-NL1, NAL-NL2 prescribes a different gain-frequency response shape, and slightly higher compression ratios are prescribed for those with mild or moderate hearing loss. NAL-NL2 further takes the profile of the hearing aid user (age, gender, and experience), language, and compressor speed into consideration.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Binaural benefits for adults who use hearing aids and cochlear implants in opposite ears.

              This study aimed to investigate 1) how a hearing aid needs to be adjusted for an adult who uses a cochlear implant in the contralateral ear; 2) whether the use of a hearing aid with a cochlear implant leads to interference; and 3) whether adults derive binaural benefits from using a hearing aid with a cochlear implant for speech perception, localization, and functional performance in everyday life. Twenty-one adults (11 female and 10 male) who used either a Nucleus CI-22 (N = 3) or a Nucleus CI-24 (N = 18) cochlear implant system in one ear participated in this study. Twelve of the adults were experienced hearing aid and implant users, whereas nine did not use a hearing aid after implantation. The hearing aids were fitted using the NAL-NL1 prescription, and fine-tuned for each individual by using a paired-comparisons test to identify the frequency response that was best for understanding speech, and a loudness balancing test to find the hearing aid gain that gave the same overall loudness as that perceived in the ear with a cochlear implant. Effects from using a hearing aid with a cochlear implant (bimodal hearing) were assessed by three measures. These included speech perception in noise in diotic and dichotic listening conditions, horizontal localization, and functional performance in everyday life. Performance with cochlear implant and hearing aid (CIHA) was compared with that with cochlear implant alone (CI) and hearing aid alone (HA). The NAL-NL1 prescribed appropriate frequency response slope on average, and the mean gain needed for binaural loudness balance was 4 dB lower than the prescribed gain. Individual variations in preferences suggest that it is desirable to fine-tune the hearing aid response slope and gain according to individual needs. The speech test results indicated that the CIHA scores were significantly better than the CI or the HA scores. Localization test results showed that the adults made significantly less error when locating a sound source using CIHA compared with CI or HA. Functional performance questionnaire scores for CIHA were significantly higher than CI scores or HA scores. All adults showed binaural benefits in at least one performance measure. On average, those who derived greater speech benefits also made less localization error and functioned more effectively in real life. The results clearly indicate that binaural advantages can be obtained from using a hearing aid with a cochlear implant in opposite ears. It is recommended that bimodal stimulation be standard practice for rehabilitation of adults who wear unilateral cochlear implants. A hearing aid should be fitted to the nonimplanted ear using the NAL-NL1 prescription as a starting point, and the frequency response slope and gain could be fine-tuned to suit individual needs.
                Bookmark

                Author and article information

                Journal
                Audiol Res
                AUDIO
                Audiology Research
                PAGEPress Publications, Pavia, Italy
                2039-4330
                2039-4349
                09 May 2019
                06 May 2019
                : 9
                : 1
                : 219
                Affiliations
                [1 ]Department of Otorhinolaryngology, Guglielmo da Saliceto Hospital , Piacenza, Italy
                [2 ]Advanced Bionics GmbH, European Research Center , Hannover, Germany
                Author notes
                Department of Otorhinolaryngology, Guglielmo da Saliceto Hospital, Via Cantone del Cristo 40, 29121 Piacenza, Italy. +39.0523.303262 - +39.0523.303273. alessandra_murri@ 123456libero.it

                Contributions: the authors contributed equally.

                Conflict of interest: Josef Chalupper declares grants from Advanced Bionics. The other authors did not receive any grants from Advanced Bionics.

                Article
                10.4081/audiores.2019.219
                6536834
                31183024
                89817bc3-475e-496b-a1fe-f96b7f4db197
                ©Copyright D. Cuda et al., 2019

                This article is distributed under the terms of the Creative Commons Attribution Noncommercial License ( by-nc 4.0) which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

                History
                : 21 January 2019
                : 12 March 2019
                Page count
                Figures: 2, Tables: 1, Equations: 0, References: 18, Pages: 4
                Funding
                Funding: Advanced Bionics provided the Hearing Aid Naida link UP for the duration of the study.
                Categories
                Article

                cochlear implant,bimodal fitting formula,clinical efficiency

                Comments

                Comment on this article