          Abstract

          Purpose: The endovascular treatment of intracranial aneurysms was proven safe and effective compared to the alternative method of surgical clipping, despite the high recurrence rate. Follow-up of embolized intracranial aneurysms is mandatory for the early detection of recurrence and improved outcomes. DSA is used as the reference standard for this assessment. To determine the effectiveness of MRA in follow-up evaluations of intracranial aneurysms after embolization by comparing DSA, CE-MRA, and TOF-MRA.

          Materials and Methods: Sixty-eight consecutive patients undergoing DSA, TOF-MRA, and CE-MRA during an interval of <1 week were enrolled in this 6-month study. Images were evaluated for occlusion status, patency of the parent vessels, and artifacts. The modified Raymond-Roy occlusion classification and Aneurysm Embolization Grades were used to assess the occlusion status and initial DSA images for detection of recurrence in two filtered study phases with optimized selection criteria. Seventeen observers (phase I: 9, phase II: 8) independently interpreted the double-blinded images. Agreement was expressed with a Fleiss kappa value; p < 0.05 was considered significant.

          Results: This study included 68 patients with 77 aneurysms; 38 (49.35%) were treated with coil alone and 39 (50.65%) with stent-assisted coiling. In both phases, DSA was superior to TOF-MRA and CE-MRA using MRRC (Phase I: k = 0.567, p ≤ 0.001; k = 0.287, p ≤ 0.001; k = 0.117, p ≤ 0.001, respectively; Phase II: k = 0.503, p ≤ 0.001; k = 0.303, p ≤ 0.001; k = 0.115, p = 0.038, respectively). TOF-MRA was as effective as DSA (TOF: k = 0.335, p ≤ 0.001; DSA: k = 0.323, p ≤ 0.001) for recurrence detection.

          Conclusion: We suggest TOF-MRA as a first-line follow-up tool to detect aneurysm recurrence, and DSA to quantify the filling space to make a definite decision on re-embolization.

          Related collections

          Most cited references42

          • Record: found
          • Abstract: found
          • Article: not found

          The measurement of observer agreement for categorical data.

          This paper presents a general statistical methodology for the analysis of multivariate categorical data arising from observer reliability studies. The procedure essentially involves the construction of functions of the observed proportions which are directed at the extent to which the observers agree among themselves and the construction of test statistics for hypotheses involving these functions. Tests for interobserver bias are presented in terms of first-order marginal homogeneity and measures of interobserver agreement are developed as generalized kappa-type statistics. These procedures are illustrated with a clinical diagnosis example from the epidemiological literature.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Understanding interobserver agreement: the kappa statistic.

            Items such as physical exam findings, radiographic interpretations, or other diagnostic tests often rely on some degree of subjective interpretation by observers. Studies that measure the agreement between two or more observers should include a statistic that takes into account the fact that observers will sometimes agree or disagree simply by chance. The kappa statistic (or kappa coefficient) is the most commonly used statistic for this purpose. A kappa of 1 indicates perfect agreement, whereas a kappa of 0 indicates agreement equivalent to chance. A limitation of kappa is that it is affected by the prevalence of the finding under observation. Methods to overcome this limitation have been described.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils.

              Our aim in this study was to assess the incidence and determining factors of angiographic recurrences after endovascular treatment of aneurysms. A retrospective analysis of all patients with selective endosaccular coil occlusion of intracranial aneurysms prospectively collected from 1992 to 2002 was performed. There were 501 aneurysms in 466 patients (mean+/-SD age, 54.20+/-12.54 years; 74% female). Aneurysms were acutely ruptured (54.1%) or unruptured (45.9%). Mean+/-SD aneurysm size was 9.67+/-5.91 mm with a 4.31+/-1.97-mm neck. The most frequent sites were basilar bifurcation (27.7%) and carotid ophthalmic (18.0%) aneurysms. Recurrences were subjectively divided into minor and major (ideally necessitating re-treatment). The most significant predictors of angiographic recurrence were determined by logistic regression. These results were confirmed by chi2, t tests, or ANOVAs followed, when appropriate, by Tukey's contrasts. Short-term ( 1 year) follow-up angiograms, in 277 (55%), for a total of 383 (76.5%) followed up. Recurrences were found in 33.6% of treated aneurysms that were followed up and that appeared at a mean+/-SD time of 12.31+/-11.33 months after treatment. Major recurrences presented in 20.7% and appeared at a mean of 16.49+/-15.93 months. Three patients (0.8%) bled during a mean clinical follow-up period of 31.32+/-24.96 months. Variables determined to be significant predictors (P or =10 mm, treatment during the acute phase of rupture, incomplete initial occlusions, and duration of follow-up. Long-term monitoring of patients treated by endosaccular coiling is mandatory.
                Bookmark

                Author and article information

                Contributors
                Journal
                J Interv Med
                J Interv Med
                Journal of Interventional Medicine
                Shanghai Journal of Interventional Radiology Press
                2096-3602
                2590-0293
                30 April 2019
                February 2018
                30 April 2019
                : 1
                : 1
                : 32-41
                Affiliations
                [1 ]East Campus of Zhengzhou University, Zhengzhou, China.
                [2 ]Department of Intervention Neuroradiology, The First Affiliated Hospital of Zhengzhou university, Zhengzhou, China.
                [3 ]Department of Environmental Health and Ecological Science, Ifakara Health Institute, Ifakara, Morogoro, Tanzania.
                Author notes
                [* ]Correspondence: Sheng Guan, MD, PhD, Director, Department of Intervention Neuroradiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China. Email: gsradio@126.com gsradio@ 123456126.com
                Article
                S2096-3602(19)30008-0
                10.19779/j.cnki.2096-3602.2018.01.08
                8586576
                34805829
                81c6ff55-dbe4-4627-99ce-f64e2befd46d
                © 2018 Shanghai Journal of Interventional Medicine Press. Production and hosting by Elsevier B.V. on behalf of KeAi.

                This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

                History
                Categories
                Clinical Study

                effectiveness,follow-up,intracranial aneurysms,mra,dsa
                effectiveness, follow-up, intracranial aneurysms, mra, dsa

                Comments

                Comment on this article