      Permeation and destructive effects of disinfectants on protective gloves.

      1 , ,
      Contact dermatitis
      Wiley

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          In working situations where there is a possibility of acquiring blood-borne infections, the use of disinfectants is important. It is also important to use protective gloves, both to protect the skin against disinfectants and to protect against infections. Changes in the structure of the glove material may, however, interfere with the protective capability of the gloves. The influence of 4 disinfectants on the material structure and protective effect of 6 different brands of protective gloves was studied. The proposed International Organization for Standardization (ISO) standard method for determining the liquid chemical resistance of air-impermeable materials was used for permeation testing. Pieces of latex and vinyl glove were also exposed to isopropanol and ethanol for 10, 30 and 60 min and then viewed in a scanning electron microscope. Isopropanol permeated through latex and vinyl gloves in less than 10 min. The polyethylene (PE) gloves were of quite variable quality, and the breakthrough time ranged from 4 to greater than 240 min. The latex and vinyl gloves were also permeated by ethanol, but at a much lower rate. The disinfectants Blifacid, based on p-chloro-m-cresol, and Cidex, based on glutaraldehyde, did not permeate any of the gloves tested within 60 min. Isopropanol had a destructive effect on the material, which became opaque, stiff and brittle. This change in structure was verified with the scanning electron microscope. The tested gloves of latex, vinyl and PE, gave acceptable protection from contact with Blifacid and Cidex for at least 60 min. The same gloves do not give any total protection from contact with isopropanol and ethanol.

          Related collections

          Author and article information

          Journal
          Contact Dermatitis
          Contact dermatitis
          Wiley
          0105-1873
          0105-1873
          Mar 1992
          : 26
          : 3
          Affiliations
          [1 ] National Corporation of Swedish Pharmacies, Stockholm.
          Article
          10.1111/j.1600-0536.1992.tb00287.x
          1505181
          8138b93a-41f8-4dc0-9996-cd77e38091bf
          History

          Comments

          Comment on this article