0
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Measurement of the longitudinal diffusion of ionization electrons in the MicroBooNE detector

      , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
      Journal of Instrumentation
      IOP Publishing

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, D L, in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of ∼70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure D L = 3.74 +0.28 -0.29 cm 2/s.

          Related collections

          Most cited references21

          • Record: found
          • Abstract: not found
          • Article: not found

          Motion of Gaseous Ions in Strong Electric Fields

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Design and construction of the MicroBooNE detector

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Electron transport measurements in methane using an improved pulsed Townsend technique

                Bookmark

                Author and article information

                Journal
                Journal of Instrumentation
                J. Inst.
                IOP Publishing
                1748-0221
                September 22 2021
                September 01 2021
                September 22 2021
                September 01 2021
                : 16
                : 09
                : P09025
                Article
                10.1088/1748-0221/16/09/P09025
                7dc919d5-2fa8-4388-b3c8-2588c0f90145
                © 2021

                http://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article