      Testing the analytical performance of handheld XRF using marine sediments of IODP Expedition 355

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Obtaining geochemical profiles using X-ray fluorescent (XRF) techniques has become a standard procedure in many sediment core studies. The resulting datasets are not only important tools for palaeoclimatic and palaeoceanographic reconstructions, but also for stratigraphic correlation. The International Ocean Discovery Program (IODP) has therefore recently introduced shipboard application of a handheld XRF device, making geochemical data directly available to the science party. In all XRF scanning techniques, the physical properties of wet core halves cause substantial analytical deviations. In order to obtain estimates of element concentrations (e.g. for quantitative analyses of fluxes or mass-balance calculations), a calibration of the scanning data is required. We test whether results from the handheld XRF analysis on discrete samples are suitable for calibrating scanning data. Log-ratios with Ca as a common denominator were calculated. The comparison between the handheld device and conventional measurements show that the latter provide high-quality data describing Al, Si, K, Ca, Ti, Mn, Fe, Zn, Rb and Sr content ( R 2 compared with conventional measurements: ln(Al/Ca) = 0.99, ln(Si/Ca) = 0.98, ln(K/Ca) = 0.99, ln(Ti/Ca) = 0.99, ln(Mn/Ca) = 0.99, ln(Fe/Ca) = 0.99, ln(Zn/Ca) = 0.99 and ln(Sr/Ca) = 0.99). Our results imply that discrete measurements using the shipboard handheld analyser are suitable for the calibration of XRF scanning data. Our test was performed on downcore sediments from IODP Expedition 355 that display a wide variety of lithologies of both terrestrial and marine origin. The implication is that our findings are valid on a general scale and that shipboard handheld XRF analysis on discrete samples should be used for calibrating XRF scanning data.

          Related collections

          Most cited references12

          • Record: found
          • Abstract: not found
          • Article: not found

          Global Multi-Resolution Topography synthesis

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            1994 COMPILATION OF WORKING VALUES AND SAMPLE DESCRIPTION FOR 383 GEOSTANDARDS

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Influence of the water content on X-ray fluorescence core-scanning measurements in soft marine sediments

                Bookmark

                Author and article information

                Journal
                Geological Magazine
                Geol. Mag.
                Cambridge University Press (CUP)
                0016-7568
                1469-5081
                April 04 2019
                : 1-5
                Article
                10.1017/S0016756819000189
                7ad5c225-19b2-456c-a0b8-c76ccb50f668
                © 2019

                https://www.cambridge.org/core/terms

                History

                Comments

                Comment on this article