          Abstract

          We introduce in this paper a novel polyp localization method for colonoscopy videos. Our method is based on a model of appearance for polyps which defines polyp boundaries in terms of valley information. We propose the integration of valley information in a robust way fostering complete, concave and continuous boundaries typically associated to polyps. This integration is done by using a window of radial sectors which accumulate valley information to create WM-DOVA (Window Median Depth of Valleys Accumulation) energy maps related with the likelihood of polyp presence. We perform a double validation of our maps, which include the introduction of two new databases, including the first, up to our knowledge, fully annotated database with clinical metadata associated. First we assess that the highest value corresponds with the location of the polyp in the image. Second, we show that WM-DOVA energy maps can be comparable with saliency maps obtained from physicians' fixations obtained via an eye-tracker. Finally, we prove that our method outperforms state-of-the-art computational saliency results. Our method shows good performance, particularly for small polyps which are reported to be the main sources of polyp miss-rate, which indicates the potential applicability of our method in clinical practice.

          Related collections

          Author and article information

          Journal
          Comput Med Imaging Graph
          Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
          Elsevier BV
          1879-0771
          0895-6111
          Jul 2015
          : 43
          Affiliations
          [1 ] Computer Science, Department of Universitat Autònoma de Barcelona and Computer, Vision Center, Barcelona, Spain. Electronic address: jbernal@cvc.uab.es.
          [2 ] Computer Science, Department of Universitat Autònoma de Barcelona and Computer, Vision Center, Barcelona, Spain.
          [3 ] Endoscopy Unit, Gastroenterology Service, CIBERHED, IDIBAPS, Hospital Clinic, Universidad de Barcelona, Barcelona, Spain.
          Article
          S0895-6111(15)00056-7
          10.1016/j.compmedimag.2015.02.007
          25863519
          79be3e15-3aec-4352-823a-05288ed0e8c7
          History

          Colonoscopy,Valley detection,Saliency,Polyp localization,Energy maps

          Comments