1
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      The Seven Deadly Sins of Measuring Brain Structural Connectivity Using Diffusion MRI Streamlines Fibre-Tracking

      review-article
      1 , 2 , 3 , 4
      Diagnostics
      MDPI
      fibre-tracking, tractogram, connectivity, tractography, streamlines

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          There is great interest in the study of brain structural connectivity, as white matter abnormalities have been implicated in many disease states. Diffusion magnetic resonance imaging (MRI) provides a powerful means to characterise structural connectivity non-invasively, by using a fibre-tracking algorithm. The most widely used fibre-tracking strategy is based on the step-wise generation of streamlines. Despite their popularity and widespread use, there are a number of practical considerations that must be taken into account in order to increase the robustness of streamlines tracking results, particularly when these methods are used to study brain structural connectivity, and the connectome. This review article describes what we consider the ‘seven deadly sins’ of mapping structural connections using diffusion MRI streamlines fibre-tracking, with particular emphasis on ‘sins’ that can be practically avoided and they can have an important impact in the results. It is shown that there are important ‘deadly sins’ to be avoided at every step of the pipeline, such as during data acquisition, during data modelling to estimate local fibre architecture, during the fibre-tracking process itself, and during quantification of the tracking results. The recommendations here are intended to inform users on potential important shortcomings of their current tracking protocols, as well as to guide future users on some of the key issues and decisions that must be faced when designing their processing pipelines.

          Related collections

          Most cited references35

          • Record: found
          • Abstract: found
          • Article: not found

          Robust determination of the fibre orientation distribution in diffusion MRI: non-negativity constrained super-resolved spherical deconvolution.

          Diffusion-weighted (DW) MR images contain information about the orientation of brain white matter fibres that potentially can be used to study human brain connectivity in vivo using tractography techniques. Currently, the diffusion tensor model is widely used to extract fibre directions from DW-MRI data, but fails in regions containing multiple fibre orientations. The spherical deconvolution technique has recently been proposed to address this limitation. It provides an estimate of the fibre orientation distribution (FOD) by assuming the DW signal measured from any fibre bundle is adequately described by a single response function. However, the deconvolution is ill-conditioned and susceptible to noise contamination. This tends to introduce artefactual negative regions in the FOD, which are clearly physically impossible. In this study, the introduction of a constraint on such negative regions is proposed to improve the conditioning of the spherical deconvolution. This approach is shown to provide FOD estimates that are robust to noise whilst preserving angular resolution. The approach also permits the use of super-resolution, whereby more FOD parameters are estimated than were actually measured, improving the angular resolution of the results. The method provides much better defined fibre orientation estimates, and allows orientations to be resolved that are separated by smaller angles than previously possible. This should allow tractography algorithms to be designed that are able to track reliably through crossing fibre regions.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            MRtrix: Diffusion tractography in crossing fiber regions

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Anatomically-constrained tractography: improved diffusion MRI streamlines tractography through effective use of anatomical information.

              Diffusion MRI streamlines tractography suffers from a number of inherent limitations, one of which is the accurate determination of when streamlines should be terminated. Use of an accurate streamlines propagation mask from segmentation of an anatomical image confines the streamlines to the volume of the brain white matter, but does not take full advantage of all of the information available from such an image. We present a modular addition to streamlines tractography, which makes more effective use of the information available from anatomical image segmentation, and the known properties of the neuronal axons being reconstructed, to apply biologically realistic priors to the streamlines generated; we refer to this as "Anatomically-Constrained Tractography". Results indicate that some of the known false positives associated with tractography algorithms are prevented, such that the biological accuracy of the reconstructions should be improved, provided that state-of-the-art streamlines tractography methods are used. Copyright © 2012 Elsevier Inc. All rights reserved.
                Bookmark

                Author and article information

                Journal
                Diagnostics (Basel)
                Diagnostics (Basel)
                diagnostics
                Diagnostics
                MDPI
                2075-4418
                06 September 2019
                September 2019
                : 9
                : 3
                : 115
                Affiliations
                [1 ]Sydney Imaging, The University of Sydney, Sydney, New South Wales 2050, Australia; fernando.calamante@ 123456sydney.edu.au ; Tel.: +61-2-9114-4293
                [2 ]School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, New South Wales 2006, Australia
                [3 ]Florey Department of Neuroscience and Mental Health, University of Melbourne, Melbourne, Victoria 3052, Australia
                [4 ]Brain and Mind Centre, The University of Sydney, 94 Mallett Street, Camperdown, NSW 2050, Australia
                Author information
                https://orcid.org/0000-0002-7550-3142
                Article
                diagnostics-09-00115
                10.3390/diagnostics9030115
                6787694
                31500098
                7843c4ef-c187-4eb8-a179-0528d0dcb736
                © 2019 by the author.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).

                History
                : 02 July 2019
                : 04 September 2019
                Categories
                Review

                fibre-tracking,tractogram,connectivity,tractography,streamlines

                Comments

                Comment on this article