9
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      A multicenter retrospective controlled study of the Pipeline™ and Tubridge™ Flow Diverter devices for intracranial wide-necked aneurysms

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          To compare the safety and efficacy of Pipeline TM and Tubridge TM Flow Diverter devices (FDs) in the treatment of intracranial wide-necked aneurysms.

          Methods

          We retrospectively analyzed the clinical data of 92 patients with intracranial wide-necked aneurysms who were treated with those two flow-diverter devices (FDs) at four participating centers between July 2012 and December 2020.

          Results

          This study included 92 patients who underwent endovascular therapy using either Pipeline™ ( n = 39) or Tubridge TM ( n = 53) for treating intracranial wide-necked aneurysms. The periprocedural complication developed in 2.56% (1/39) patients of Pipeline group and 3.77% (2/53) patients of the Tubridge TM group. During perioperative period, one patient in Pipeline™ group showed subarachnoid hemorrhage (2.56%, 1/39) and two ischemic complications in the Tubridge™ group (3.77%, 2/53). Follow-up assessments were conducted on 31 patients (79.49%) in the Pipeline™ group (the mean follow-up period was 9.7 ± 3.3 months). The rate of complete aneurysm occlusion at the final angiographic follow-up was 77.42%. Patients with a modified Rankin scale (mRS) score of 0.44 ± 0.31. Follow-up assessments were conducted on 42 patients (79.25%) in the Tubridge TM group (the mean follow-up period was 9.1 ± 4.4 months). The rate of complete aneurysm occlusion at the final angiographic follow-up was 85.71%. Patients with mRS score of 0.52 ± 0.28. Three patients showed parent artery stenosis, and one showed parent artery occlusion.

          Conclusion

          Both the Pipeline TM and Tubridge TM are safe and effective for the treatment of intracranial wide-necked aneurysms, with no significant difference in the rate of complete aneurysm occlusion and perioperative complications between the two FDs.

          Related collections

          Most cited references23

          • Record: found
          • Abstract: found
          • Article: not found

          International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion.

          Two types of treatment are being used for patients with ruptured intracranial aneurysms: endovascular detachable-coil treatment or craniotomy and clipping. We undertook a randomised, multicentre trial to compare these treatments in patients who were suitable for either treatment because the relative safety and efficacy of these approaches had not been established. Here we present clinical outcomes 1 year after treatment. 2143 patients with ruptured intracranial aneurysms, who were admitted to 42 neurosurgical centres, mainly in the UK and Europe, took part in the trial. They were randomly assigned to neurosurgical clipping (n=1070) or endovascular coiling (n=1073). The primary outcome was death or dependence at 1 year (defined by a modified Rankin scale of 3-6). Secondary outcomes included rebleeding from the treated aneurysm and risk of seizures. Long-term follow up continues. Analysis was in accordance with the randomised treatment. We report the 1-year outcomes for 1063 of 1073 patients allocated to endovascular treatment, and 1055 of 1070 patients allocated to neurosurgical treatment. 250 (23.5%) of 1063 patients allocated to endovascular treatment were dead or dependent at 1 year, compared with 326 (30.9%) of 1055 patients allocated to neurosurgery, an absolute risk reduction of 7.4% (95% CI 3.6-11.2, p=0.0001). The early survival advantage was maintained for up to 7 years and was significant (log rank p=0.03). The risk of epilepsy was substantially lower in patients allocated to endovascular treatment, but the risk of late rebleeding was higher. In patients with ruptured intracranial aneurysms suitable for both treatments, endovascular coiling is more likely to result in independent survival at 1 year than neurosurgical clipping; the survival benefit continues for at least 7 years. The risk of late rebleeding is low, but is more common after endovascular coiling than after neurosurgical clipping.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial.

            To evaluate the safety and effectiveness of the Pipeline Embolization Device (PED; ev3/Covidien, Irvine, Calif) in the treatment of complex intracranial aneurysms. The Pipeline for Uncoilable or Failed Aneurysms is a multicenter, prospective, interventional, single-arm trial of PED for the treatment of uncoilable or failed aneurysms of the internal carotid artery. Institutional review board approval of the HIPAA-compliant study protocol was obtained from each center. After providing informed consent, 108 patients with recently unruptured large and giant wide-necked aneurysms were enrolled in the study. The primary effectiveness endpoint was angiographic evaluation that demonstrated complete aneurysm occlusion and absence of major stenosis at 180 days. The primary safety endpoint was occurrence of major ipsilateral stroke or neurologic death at 180 days. PED placement was technically successful in 107 of 108 patients (99.1%). Mean aneurysm size was 18.2 mm; 22 aneurysms (20.4%) were giant (>25 mm). Of the 106 aneurysms, 78 met the study's primary effectiveness endpoint (73.6%; 95% posterior probability interval: 64.4%-81.0%). Six of the 107 patients in the safety cohort experienced a major ipsilateral stroke or neurologic death (5.6%; 95% posterior probability interval: 2.6%-11.7%). PED offers a reasonably safe and effective treatment of large or giant intracranial internal carotid artery aneurysms, demonstrated by high rates of complete aneurysm occlusion and low rates of adverse neurologic events; even in aneurysms failing previous alternative treatments.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The durability of endovascular coiling versus neurosurgical clipping of ruptured cerebral aneurysms: 18 year follow-up of the UK cohort of the International Subarachnoid Aneurysm Trial (ISAT)

              Summary Background Previous analyses of the International Subarachnoid Aneurysm Trial (ISAT) cohort have reported on the risks of recurrent subarachnoid haemorrhage and death or dependency for a minimum of 5 years and up to a maximum of 14 years after treatment of a ruptured intracranial aneurysm with either neurosurgical clipping or endovascular coiling. At 1 year there was a 7% absolute and a 24% relative risk reduction of death and dependency in the coiling group compared with the clipping group, but the medium-term results showed the increased need for re-treatment of the target aneurysm in the patients given coiling. We report the long-term follow-up of patients in this UK cohort. Methods In ISAT, patients were randomly allocated to either neurosurgical clipping or endovascular coiling after a subarachnoid haemorrhage, assuming treatment equipoise, between Sept 12, 1994, and May 1, 2002. We followed up 1644 patients in 22 UK neurosurgical centres for death and clinical outcomes for 10·0–18·5 years. We assessed dependency as self-reported modified Rankin scale score obtained through yearly questionnaires. Data for recurrent aneurysms and rebleeding events were collected from questionnaires and from hospital and general practitioner records. The Office for National Statistics supplied data on deaths. This study is registered, number ISRCTN49866681. Findings At 10 years, 674 (83%) of 809 patients allocated endovascular coiling and 657 (79%) of 835 patients allocated neurosurgical clipping were alive (odds ratio [OR] 1·35, 95% CI 1·06–1·73). Of 1003 individuals who returned a questionnaire at 10 years, 435 (82%) patients treated with endovascular coiling and 370 (78%) patients treated with neurosurgical clipping were independent (modified Rankin scale score 0–2; OR 1·25; 95% CI 0·92–1·71). Patients in the endovascular treatment group were more likely to be alive and independent at 10 years than were patients in the neurosurgery group (OR 1·34, 95% CI 1·07–1·67). 33 patients had a recurrent subarachnoid haemorrhage more than 1 year after their initial haemorrhage (17 from the target aneurysm). Interpretation Although rates of increased dependency alone did not differ between groups, the probability of death or dependency was significantly greater in the neurosurgical group than in the endovascular group. Rebleeding was more likely after endovascular coiling than after neurosurgical clipping, but the risk was small and the probability of disability-free survival was significantly greater in the endovascular group than in the neurosurgical group at 10 years. Funding UK Medical Research Council.
                Bookmark

                Author and article information

                Contributors
                Journal
                Front Neurol
                Front Neurol
                Front. Neurol.
                Frontiers in Neurology
                Frontiers Media S.A.
                1664-2295
                13 October 2022
                2022
                : 13
                : 1014596
                Affiliations
                [1] 1Department of Neurosurgery, Shengjing Hospital of China Medical University , Shenyang, China
                [2] 2Department of Neurosurgery, General Hospital of Northern Theater Command , Shenyang, China
                [3] 3Department of Neurosurgery, First Affiliated Hospital of Dalian Medical University , Dalian, China
                [4] 4Department of Interventional Radiology, Liaohe Oilfield General Hospital , Panjin, China
                [5] 5Department of Stroke Center, First Hospital of China Medical University , Shenyang, China
                [6] 6Department of Neurology, The First Hospital of China Medical University , Shenyang, China
                [7] 7Department of Neurosurgery, The First Hospital of China Medical University , Shenyang, China
                Author notes

                Edited by: Jianmin Liu, Second Military Medical University, China

                Reviewed by: Wei Ni, Fudan University, China; Gang Luo, Capital Medical University, China; Hao Wang, Linyi People's Hospital, China

                *Correspondence: Zhiqing Li dr_lizhiqing@ 123456163.com

                This article was submitted to Endovascular and Interventional Neurology, a section of the journal Frontiers in Neurology

                Article
                10.3389/fneur.2022.1014596
                9606650
                36313488
                767decf9-5a9f-48ce-b63f-ef8ed4d96fba
                Copyright © 2022 Cai, Yang, Xu, Geng, Li, Li, Fu, Liu, Wang and Li.

                This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

                History
                : 08 August 2022
                : 26 September 2022
                Page count
                Figures: 2, Tables: 2, Equations: 0, References: 23, Pages: 8, Words: 5717
                Categories
                Neurology
                Original Research

                Neurology
                intracranial wide-necked aneurysm,flow diverter devices,coil,endovascular therapy,perioperative complications

                Comments

                Comment on this article