          Abstract

          Background

          Perioperative monitoring and hemodynamic management after heterotopic thoracic cardiac xenotransplantation is challenging due to 2 independently beating hearts. Telemetry allows continuous monitoring of hemodynamic parameters of both the donor and recipient hearts. We describe our experience and report on the validity of a telemetric system during and after surgery.

          Material/Methods

          Wireless telemetry transmitters were implanted in 3 baboons receiving porcine donor hearts. Left ventricular pressure and ECG were assessed from the donor heart, whereas aortic pressure and temperature were assessed from the recipient. Telemetric data were validated with invasive blood pressure measurements.

          Results

          Telemetric blood pressure was lower than invasive blood pressure. Intraoperatively, the probe in the graft’s left ventricle measured negative end-diastolic pressures. Telemetry allowed simple discrimination between donor’s and recipient’s heart rates. Body temperature was underestimated by telemetry. Telemetric monitoring facilitates recognition of graft arrhythmias and volume demand.

          Conclusions

          In heterotopic thoracic cardiac xenotransplantation, telemetric implants are useful tools to continuously monitor the animals’ hemodynamic parameters and to discriminate donor and recipient organs. Accuracy is sufficient for systemic pressure measurement, but perioperative use of left ventricular end-diastolic pressure as a surrogate parameter for graft function is not advisable. Temperature measurements by telemetry do not reflect body core temperature.

          Related collections

          Most cited references10

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis

          Introduction Fluid resuscitation is crucial in managing hemodynamically unstable patients. The last decade witnessed the use of pulse pressure variation (PPV) to predict fluid responsiveness. However, as far as we know, no systematic review and meta-analysis has been carried out to evaluate the value of PPV in predicting fluid responsiveness specifically upon patients admitted into intensive care units. Methods We searched MEDLINE and EMBASE and included clinical trials that evaluated the association between PPV and fluid responsiveness after fluid challenge in mechanically ventilated patients in intensive care units. Data were synthesized using an exact binomial rendition of the bivariate mixed-effects regression model modified for synthesis of diagnostic test data. Result Twenty-two studies with 807 mechanically ventilated patients with tidal volume more than 8 ml/kg and without spontaneous breathing and cardiac arrhythmia were included, and 465 were responders (58%). The pooled sensitivity was 0.88 (95% confidence interval (CI) 0.81 to 0.92) and pooled specificity was 0.89 (95% CI 0.84 to 0.92). A summary receiver operating characteristic curve yielded an area under the curve of 0.94 (95% CI 0.91 to 0.95). A significant threshold effect was identified. Conclusions PPV predicts fluid responsiveness accurately in mechanically ventilated patients with relative large tidal volume and without spontaneous breathing and cardiac arrhythmia. Electronic supplementary material The online version of this article (doi:10.1186/s13054-014-0650-6) contains supplementary material, which is available to authorized users.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Direct blood pressure measurement--dynamic response requirements.

            R. Gardner (1981)
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Prolonged Survival Following Pig-to-Primate Liver Xenotransplantation Utilizing Exogenous Coagulation Factors and Co-Stimulation Blockade.

              Since the first attempt in 1968, survival following pig-to-primate liver xenotransplantation (LXT) has been limited. We evaluated a model utilizing α-1,3-galactosyltransferase knockout donors, continuous post-transplant infusion of human prothrombin concentrate complex and immunosuppression including anti-thymocyte globulin, FK-506, methylprednisone and co-stimulation blockade (belatacept, n=3 or anti-CD40mAb, n=1) to extend survival. Baboon #1 remained well until POD25 when euthanasia was required due to cholestasis and plantar ulcers. Baboon #2 was euthanized following a seizure on POD5, despite normal LFTs and no apparent pathology. Baboon # 3 demonstrated initial stable liver function, but was euthanized on POD8 due to worsening LFTs. Pathology revealed C4d positivity, extensive hemorrhagic necrosis and a focal CMV inclusion. Baboon # 4 was clinically well with stable LFTs until POD29, when euthanasia was again necessitated by plantar ulcerations as well as rising LFTs. Final pathology was C4d negative and without evidence of rejection, inflammation or TMA. Thus, nearly one-month rejection-free survival has been achieved following LXT in 2 of 4 continuous recipients, demonstrating that the porcine liver can support life in primates for several weeks and is encouraging for potential clinical application of LXT as a bridge to allotransplantation for patients with acute-on-chronic or fulminant hepatic failure. This article is protected by copyright. All rights reserved.
                Bookmark

                Author and article information

                Journal
                Ann Transplant
                Ann. Transplant
                Annals of Transplantation
                Annals of Transplantation
                International Scientific Literature, Inc.
                1425-9524
                2329-0358
                2018
                20 July 2018
                : 23
                : 491-499
                Affiliations
                [1 ]Department of Anaesthesiology, University Hospital, Ludwig Maximilian University (LMU), Munich, Germany
                [2 ]Transregio Collaborative Research Center 127, Walter Brendel Centre of Experimental Medicine, Ludwig Maximilian University (LMU), Munich, Germany
                [3 ]Department of Cardiac Surgery, University Hospital, Ludwig Maximilian University (LMU), Munich, Germany
                [4 ]Chair of Livestock Biotechnology, School of Life Sciences Weihenstephan, Technical University of Munich, Munich, Germany
                Author notes
                Corresponding Author: Matthias Längin, e-mail: matthias.laengin@ 123456med.uni-muenchen.de
                [A]

                Study Design

                [B]

                Data Collection

                [C]

                Statistical Analysis

                [D]

                Data Interpretation

                [E]

                Manuscript Preparation

                [F]

                Literature Search

                [G]

                Funds Collection

                [*]

                Both authors contributed equally to this work

                Article
                909522
                10.12659/AOT.909522
                6248073
                30026460
                75435a91-0002-4372-b871-495300d67868
                © Ann Transplant, 2018

                This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International ( CC BY-NC-ND 4.0)

                History
                : 15 February 2018
                : 03 April 2018
                Categories
                Original Paper

                heart transplantation,monitoring,telemetry,transplantation, heterologous

                Comments

                Comment on this article