      Effectiveness and Safety of the ACURATE Neo Prosthesis in 1,000 Patients With Aortic Stenosis.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The ACURATE neo transcatheter heart valve has demonstrated a balanced profile with low rates of permanent pacemaker implantation, low risk of coronary obstruction, and favorable hemodynamic properties whilst having an acceptable rate of ≥moderate paravalvular leakage (PVL). Here, we report in-hospital results and assess the learning curve for implantation of the ACURATE neo device in a large, single-center cohort. The cohort of this retrospective, observational study comprised 1,000 consecutive patients with severe aortic stenosis who underwent transfemoral transcatheter aortic valve implantation using the ACURATE neo prosthesis between May 2012 and December 2019. We determined procedural outcomes with emphasis on PVL and analyzed the learning curve. The median age was 81.9 years [IQR 78.8; 85.1], and the Euroscore II was 4.2% [IQR 2.7; 7.3]. The rate of PVL ≥moderate measured by echocardiography at discharge was 3.7% (37 of 988). We observed a learning curve, with a decline in ≥moderate PVL from 6.7% in the first quartile to 0.8% in the last quartile, that was related to better patient selection, more oversizing, and consideration of the amount and distribution of aortic valve calcification. In this thus far largest single-center experience using the ACURATE neo prosthesis, we demonstrate that after completing a learning curve and observation of precepts that include patient selection, careful sizing, and procedural aspects, the rate of ≥moderate PVL may be reduced to <1%.

          Related collections

          Author and article information

          Journal
          Am J Cardiol
          The American journal of cardiology
          Elsevier BV
          1879-1913
          0002-9149
          Sep 15 2020
          : 131
          Affiliations
          [1 ] Kerckhoff Heart Center, Department of Cardiology, Bad Nauheim, Germany; Department of Cardiology, Justus-Liebig University of Giessen, Giessen, Germany. Electronic address: w.kim@kerckhoff-klinik.de.
          [2 ] Department of Cardiology, St. Johannes Hospital, Dortmund, Germany.
          [3 ] Kerckhoff Heart Center, Department of Cardiology, Bad Nauheim, Germany.
          [4 ] Department of Cardiac Surgery, Johann-Wolfgang-Goethe University, Frankfurt, Germany.
          [5 ] Kerckhoff Heart Center, Department of Cardiology, Bad Nauheim, Germany; Department of Cardiology, Justus-Liebig University of Giessen, Giessen, Germany.
          Article
          S0002-9149(20)30555-5
          10.1016/j.amjcard.2020.05.044
          32622500
          74534d3e-ffaa-4142-8d7e-769aaf7d0822
          History

          Comments

          Comment on this article