      Flexible Multi-Turn Multi-Gap Coaxial RF Coils: Design Concept and Implementation for Magnetic Resonance Imaging at 3 and 7 Tesla

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references53

          • Record: found
          • Abstract: found
          • Article: not found

          Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout.

          In MRI, the transmit radiofrequency field (B(1)(+)) inhomogeneity can lead to signal intensity variations and quantitative measurement errors. By independently mapping the local B(1)(+) variation, the radiofrequency-related signal variations can be corrected for. In this study, we present a new fast B(1)(+) mapping method using a slice-selective preconditioning radiofrequency pulse. Immediately after applying a slice-selective preconditioning pulse, a turbo fast low-angle-shot imaging sequence with centric k-space reordering is performed to capture the residual longitudinal magnetization left behind by the slice-selective preconditioning pulse due to B(1)(+) variation. Compared to the reference double-angle method, this method is considerably faster. Specifically, the total scan time for the double-angle method is equal to the product of 2 (number of images), the number of phase-encoding lines, and approximately 5T(1), whereas the slice-selective preconditioning method takes approximately 5T(1). This method was validated in vitro and in vivo with a 3-T whole-body MRI system. The combined brain and pelvis B(1)(+) measurements showed excellent agreement and strong correlation with those by the double-angle method (mean difference = 0.025; upper and lower 95% limits of agreement were -0.07 and 0.12; R = 0.93; P < 0.001). This fast B(1)(+) mapping method can be used for a variety of applications, including body imaging where fast imaging is desirable.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Screen-printed flexible MRI receive coils

            Magnetic resonance imaging is an inherently signal-to-noise-starved technique that limits the spatial resolution, diagnostic image quality and results in typically long acquisition times that are prone to motion artefacts. This limitation is exacerbated when receive coils have poor fit due to lack of flexibility or need for padding for patient comfort. Here, we report a new approach that uses printing for fabricating receive coils. Our approach enables highly flexible, extremely lightweight conforming devices. We show that these devices exhibit similar to higher signal-to-noise ratio than conventional ones, in clinical scenarios when coils could be displaced more than 18 mm away from the body. In addition, we provide detailed material properties and components performance analysis. Prototype arrays are incorporated within infant blankets for in vivo studies. This work presents the first fully functional, printed coils for 1.5- and 3-T clinical scanners.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              7-T MR--from research to clinical applications?

              Over 20,000 MR systems are currently installed worldwide and, although the majority operate at magnetic fields of 1.5 T and below (i.e. about 70%), experience with 3-T (in high-field clinical diagnostic imaging and research) and 7-T (research only) human MR scanners points to a future in functional and metabolic MR diagnostics. Complementary to previous studies, this review attempts to provide an overview of ultrahigh-field MR research with special emphasis on emerging clinical applications at 7 T. We provide a short summary of the technical development and the current status of installed MR systems. The advantages and challenges of ultrahigh-field MRI and MRS are discussed with special emphasis on radiofrequency inhomogeneity, relaxation times, signal-to-noise improvements, susceptibility effects, chemical shifts, specific absorption rate and other safety issues. In terms of applications, we focus on the topics most likely to gain significantly from 7-T MR, i.e. brain imaging and spectroscopy and musculoskeletal imaging, but also body imaging, which is particularly challenging. Examples are given to demonstrate the advantages of susceptibility-weighted imaging, time-of-flight MR angiography, high-resolution functional MRI, (1)H and (31)P MRSI in the human brain, sodium and functional imaging of cartilage and the first results (and artefacts) using an eight-channel body array, suggesting future areas of research that should be intensified in order to fully explore the potential of 7-T MR systems for use in clinical diagnosis. Copyright © 2011 John Wiley & Sons, Ltd.
                Bookmark

                Author and article information

                Journal
                IEEE Transactions on Medical Imaging
                IEEE Trans. Med. Imaging
                Institute of Electrical and Electronics Engineers (IEEE)
                0278-0062
                1558-254X
                April 2021
                April 2021
                : 40
                : 4
                : 1267-1278
                Article
                10.1109/TMI.2021.3051390
                33439836
                71462a6e-91ff-437e-9dce-e30b06db2fc7
                © 2021

                https://creativecommons.org/licenses/by/4.0/legalcode

                History

                Comments

                Comment on this article