      Aged, Aged, 80 and over, Antihypertensive Agents, administration & dosage, Cataract, complications, Female, Follow-Up Studies, Glaucoma Drainage Implants, Glaucoma, Open-Angle, physiopathology, surgery, Humans, Intraocular Pressure, physiology, Male, Middle Aged, Ocular Hypertension, Phacoemulsification, Prospective Studies, Visual Acuity

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To evaluate the mid-term efficacy and safety of the GTS-400-iStent combined with phacoemulsification in patients with cataract and open-angle glaucoma (OAG) or ocular hypertension (OHT). Prospective, non-comparative, uncontrolled, interventional case series study. Subjects underwent phacoemulsification and two GTS-400 implantation. Efficacy outcomes: intraocular pressure (IOP) and antiglaucoma medications. Safety outcomes: complications, best-corrected visual acuity and endothelial cell count (ECC). Follow-up was 1 year. 20 patients were enrolled (mean age: 75.1 ± 8.6 years). Mean medicated baseline IOP was 19.95 ± 3.71 mm Hg and 26 ± 3.11 mm Hg without medication. Mean final IOP was 16.75 ± 2.24, determining a final IOP decrease of 35.68% (9.42 ± 3 mm Hg; p<0.001), from baseline washout IOP. Mean number of medications fell from 1.3 ± 0.66 to 0.3 ± 0.57 (P<0.001). 75% of patients were off medications at one year. Mean ECC decreased from 2289.64 ± 393.5 cells/mm(2) to 1986.95 ± 520.58 cells/mm(2). Combined cataract surgery with implantation of GTS-400-iStent seems to be an effective and safe procedure.

          Related collections

          Author and article information

          Comments

          Comment on this article

          scite_
          87
          1
          60
          0
          Smart Citations
          87
          1
          60
          0
          Citing PublicationsSupportingMentioningContrasting
          View Citations

          See how this article has been cited at scite.ai

          scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

          Similar content666

          Cited by34