          Abstract

          BACKGROUND

          Advances in implant material and design have allowed for improvements in total knee arthroplasty (TKA) outcomes. A cruciate retaining (CR) TKA provides the least constraint of TKA designs by preserving the native posterior cruciate ligament. Limited research exists that has examined clinical outcomes or patient reported outcome measures (PROMs) of a large cohort of patients undergoing a CR TKA utilizing a kinematically designed implant. It was hypothesized that the studied CR Knee System would demonstrate favorable outcomes and a clinically significant improvement in pain and functional scores.

          AIM

          To assess both short-term and mid-term clinical outcomes and PROMs of a novel CR TKA design.

          METHODS

          A retrospective, multi-surgeon study identified 255 knees undergoing a TKA utilizing a kinematically designed CR Knee System (JOURNEY™ II CR; Smith and Nephew, Inc., Memphis, TN) at an urban, academic medical institution between March 2015 and July 2021 with a minimum of two-years of clinical follow-up with an orthopedic surgeon. Patient demographics, surgical information, clinical outcomes, and PROMs data were collected via query of electronic medical records. The PROMs collected in the present study included the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) and Patient-Reported Outcomes Measurement Information System (PROMIS ®) scores. The significance of improvements in mean PROM scores from preoperative scores to scores collected at six months and two-years postoperatively was analyzed using Independent Samples t-tests.

          RESULTS

          Of the 255 patients, 65.5% were female, 43.8% were White, and patients had an average age of 60.6 years. Primary osteoarthritis (96.9%) was the most common primary diagnosis. The mean surgical time was 105.3 minutes and mean length of stay was 2.1 d with most patients discharged home (92.5%). There were 18 emergency department (ED) visits within 90 d of surgery resulting in a 90 d ED visit rate of 7.1%, including a 2.4% orthopedic-related ED visit rate and a 4.7% non-orthopedic-related ED visit rate. There were three (1.2%) hospital readmissions within 90 d postoperatively. With a mean time to latest follow-up of 3.3 years, four patients (1.6%) required revision, two for arthrofibrosis, one for aseptic femoral loosening, and one for peri-prosthetic joint infection. There were significant improvements in KOOS JR, PROMIS Pain Intensity, PROMIS Pain Interference, PROMIS Mobility, and PROMIS Physical Health from preoperative scores to six month and two-year postoperative scores.

          CONCLUSION

          The evaluated implant is an effective, novel design offering excellent outcomes and low complication rates. At a mean follow up of 3.3 years, four patients required revisions, three aseptic and one septic, resulting in an overall implant survival rate of 98.4% and an aseptic survival rate of 98.8%. The results of our study demonstrate the utility of this kinematically designed implant in the setting of primary TKA.

          Related collections

          Most cited references21

          • Record: found
          • Abstract: found
          • Article: not found

          The John Insall Award: Patient expectations affect satisfaction with total knee arthroplasty.

          Satisfaction with the outcome of total knee arthroplasty is highly variable, with a small but significant percentage of patients reporting dissatisfaction with the procedure. The purpose of this study was to determine which factors contribute to patient satisfaction with total knee replacement (TKR), and their relative importance. At a minimum of 1 year post unilateral primary TKR, 253 patients completed a self-administered, validated "Knee Function Questionnaire," which examined each patient's participation in a broad range of activities involving the knee, their level of satisfaction, and the extent to which TKR had fulfilled their expectations. The association between function, expectation and satisfaction was examined using univariate and multivariate logistic regression. Seventy-five percent of patients were either "satisfied" or "very satisfied" with their knee replacement, while 14% were "dissatisfied" or "very dissatisfied." Satisfaction correlated significantly (p < 0.001) with age less than 60, absence of residual symptoms, fulfillment of expectations, and absence of functional impairment. Satisfaction with TKR is primarily determined by patients' expectations, and not their absolute level of function. Real improvements in the outcome of TKA must address prevention of residual pain, stiffness and swelling, and each patient's preoperative concept of the likely outcome of these procedures.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Patient satisfaction after knee arthroplasty: a report on 27,372 knees operated on between 1981 and 1995 in Sweden.

            During a validation process of the Swedish Knee Arthroplasty Register (SKAR), living registered patients were sent a questionnaire to ask if they had been reoperated on. This gave an opportunity to pose a simple four-point question with respect to patient satisfaction which 95% of patients answered. We analyzed the answers of patients operated on between 1981 and 1995 and found that only 8% of the patients were dissatisfied regarding their knee arthroplasty 2-17 years postoperatively. The satisfaction rate was constant, regardless of when the operation had been performed during the 15-year period. The proportion of satisfied patients was affected by the preoperative diagnosis, patients operated on for a long-standing disease more often being satisfied than those with a short disease-duration. There was no difference in proportions of satisfied patients, whether they had primarily been operated on with a total knee arthroplasty (TKA) or a medial unicompartmental arthroplasty (UKA). For TKAs performed with primary patellar resurfacing, there was a higher ratio of satisfied patients than for TKAs not resurfaced, but this increased ratio diminished with time passed since the primary operation. Unrevised knees had a higher proportion of satisfied patients than knees that had been subject to revision, and among patients revised for medial UKA, the proportion of satisfied patients was higher than among patients revised for TKA. We conclude that satisfaction after knee arthroplasty is stable and long-lasting in unrevised cases and that even after revision most patients are satisfied.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Periprosthetic Joint Infection Is the Main Cause of Failure for Modern Knee Arthroplasty: An Analysis of 11,134 Knees.

              Although large series from national joint registries may accurately reflect indications for revision TKAs, they may lack the granularity to detect the true incidence and relative importance of such indications, especially periprosthetic joint infections (PJI).
                Bookmark

                Author and article information

                Contributors
                Journal
                World J Orthop
                WJO
                World Journal of Orthopedics
                Baishideng Publishing Group Inc
                2218-5836
                18 February 2024
                18 February 2024
                : 15
                : 2
                : 118-128
                Affiliations
                Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Orthopedic Hospital, NYU Langone Health, New York, NY 10010, United States
                Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Orthopedic Hospital, NYU Langone Health, New York, NY 10010, United States
                Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Orthopedic Hospital, NYU Langone Health, New York, NY 10010, United States
                Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Orthopedic Hospital, NYU Langone Health, New York, NY 10010, United States
                Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Orthopedic Hospital, NYU Langone Health, New York, NY 10010, United States
                Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Orthopedic Hospital, NYU Langone Health, New York, NY 10010, United States
                Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Orthopedic Hospital, NYU Langone Health, New York, NY 10010, United States. ran.schwarzkopf@ 123456nyulangone.org
                Author notes

                Author contributions: All authors contributed to the study conception and design; Material preparation, data collection and analysis were performed by Katzman JL, Habibi AA, Haider MA, Cardillo C, Fernandez-Madrid I, Meftah M, Schwarzkopf R; The first draft of the manuscript was written by Katzman JL and Habibi AA; Haider MA, Cardillo C, Fernandez-Madrid I, Meftah M, and Schwarzkopf R wrote, reviewed, and revised parts of the manuscript; All authors read and approved the final manuscript.

                Corresponding author: Ran Schwarzkopf, MD, MSc, Professor, Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Orthopedic Hospital, NYU Langone Health, 301 East 17 th Street, Suite 1402, New York, NY 10010, United States. ran.schwarzkopf@ 123456nyulangone.org

                Article
                jWJO.v15.i2.pg118 88887
                10.5312/wjo.v15.i2.118
                10921185
                38464356
                6db4fb78-c6dd-43c6-8fc0-d44df8d775c9
                ©The Author(s) 2024. Published by Baishideng Publishing Group Inc. All rights reserved.

                This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/

                History
                : 13 October 2023
                : 15 December 2023
                : 9 January 2024
                Categories
                Retrospective Study

                total knee arthroplasty,cruciate retaining,kinematic design,survivorship,bearing material,prosthetic design,clinical outcomes,patient-reported outcome measures