11
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      A novel MRI-based data fusion methodology for efficient, personalised, compliant simulations of aortic haemodynamics

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We present a novel, cost-efficient methodology to simulate aortic haemodynamics in a patient-specific, compliant aorta using an MRI data fusion process. Based on a previously-developed Moving Boundary Method, this technique circumvents the high computational cost and numerous structural modelling assumptions required by traditional Fluid-Structure Interaction techniques. Without the need for Computed Tomography (CT) data, the MRI images required to construct the simulation can be obtained during a single imaging session. Black Blood MR Angiography and 2D Cine-MRI data were used to reconstruct the luminal geometry and calibrate wall movement specifically to each region of the aorta. 4D-Flow MRI and non-invasive pressure measurements informed patient-specific inlet and outlet boundary conditions. Luminal area closely matched 2D Cine-MRI measurements with a mean error of less than 4.6% across the cardiac cycle, while physiological pressure and flow distributions were simulated to within 3.3% of patient-specific targets. Moderate agreement with 4D-Flow MRI velocity data was observed. Despite lower peak velocity, an equivalent rigid-wall simulation predicted a mean Time-Averaged Wall Shear Stress (TAWSS) 13% higher than the compliant simulation. The agreement observed between compliant simulation results and MRI data is testament to the accuracy and efficiency of this MRI-based simulation technique.

          Related collections

          Most cited references46

          • Record: found
          • Abstract: found
          • Article: not found

          4D flow MRI.

          Traditionally, magnetic resonance imaging (MRI) of flow using phase contrast (PC) methods is accomplished using methods that resolve single-directional flow in two spatial dimensions (2D) of an individual slice. More recently, three-dimensional (3D) spatial encoding combined with three-directional velocity-encoded phase contrast MRI (here termed 4D flow MRI) has drawn increased attention. 4D flow MRI offers the ability to measure and to visualize the temporal evolution of complex blood flow patterns within an acquired 3D volume. Various methodological improvements permit the acquisition of 4D flow MRI data encompassing individual vascular structures and entire vascular territories such as the heart, the adjacent aorta, the carotid arteries, abdominal, or peripheral vessels within reasonable scan times. To subsequently analyze the flow data by quantitative means and visualization of complex, three-directional blood flow patterns, various tools have been proposed. This review intends to introduce currently used 4D flow MRI methods, including Cartesian and radial data acquisition, approaches for accelerated data acquisition, cardiac gating, and respiration control. Based on these developments, an overview is provided over the potential this new imaging technique has in different parts of the body from the head to the peripheral arteries. Copyright © 2012 Wiley Periodicals, Inc.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Validation of a one-dimensional model of the systemic arterial tree.

            A distributed model of the human arterial tree including all main systemic arteries coupled to a heart model is developed. The one-dimensional (1-D) form of the momentum and continuity equations is solved numerically to obtain pressures and flows throughout the systemic arterial tree. Intimal shear is modeled using the Witzig-Womersley theory. A nonlinear viscoelastic constitutive law for the arterial wall is considered. The left ventricle is modeled using the varying elastance model. Distal vessels are terminated with three-element windkessels. Coronaries are modeled assuming a systolic flow impediment proportional to ventricular varying elastance. Arterial dimensions were taken from previous 1-D models and were extended to include a detailed description of cerebral vasculature. Elastic properties were taken from the literature. To validate model predictions, noninvasive measurements of pressure and flow were performed in young volunteers. Flow in large arteries was measured with MRI, cerebral flow with ultrasound Doppler, and pressure with tonometry. The resulting 1-D model is the most complete, because it encompasses all major segments of the arterial tree, accounts for ventricular-vascular interaction, and includes an improved description of shear stress and wall viscoelasticity. Model predictions at different arterial locations compared well with measured flow and pressure waves at the same anatomical points, reflecting the agreement in the general characteristics of the "generic 1-D model" and the "average subject" of our volunteer population. The study constitutes a first validation of the complete 1-D model using human pressure and flow data and supports the applicability of the 1-D model in the human circulation.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The influence of the non-Newtonian properties of blood on the flow in large arteries: steady flow in a carotid bifurcation model.

              Laser Doppler anemometry experiments and finite element simulations of steady flow in a three dimensional model of the carotid bifurcation were performed to investigate the influence of non-Newtonian properties of blood on the velocity distribution. The axial velocity distribution was measured for two fluids: a non-Newtonian blood analog fluid and a Newtonian reference fluid. Striking differences between the measured flow fields were found. The axial velocity field of the non-Newtonian fluid was flattened, had lower velocity gradients at the divider wall, and higher velocity gradients at the non-divider wall. The flow separation, as found with the Newtonian fluid, was absent. In the computations, the shear thinning behavior of the analog blood fluid was incorporated through the Carreau-Yasuda model. The viscoelastic properties of the fluid were not included. A comparison between the experimental and numerical results showed good agreement, both for the Newtonian and the non-Newtonian fluid. Since only shear thinning was included, this seems to be the dominant non-Newtonian property of the blood analog fluid under steady flow conditions.
                Bookmark

                Author and article information

                Contributors
                Journal
                J Biomech
                J Biomech
                Journal of Biomechanics
                Elsevier Science
                0021-9290
                1873-2380
                02 December 2021
                02 December 2021
                : 129
                : 110793
                Affiliations
                [a ]Mechanical Engineering Department, Roberts Engineering Building, University College London, Torrington Place, London, WC1E 7JE, United Kingdom
                [b ]Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), Charles Bell House, London, W1W 7TY, United Kingdom
                [c ]School of Life Science, Beijing Institute of Technology, Beijing, China
                [d ]Department of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing, China
                Author notes
                [* ]Corresponding author at: Mechanical Engineering Department, Roberts Engineering Building, University College London, Torrington Place, London, WC1E 7JE, United Kingdom. v.diaz@ 123456ucl.ac.uk
                Article
                S0021-9290(21)00555-8 110793
                10.1016/j.jbiomech.2021.110793
                8907869
                34715606
                6ceccc4e-9237-40c1-b3a7-a492169a3019
                © 2021 The Authors

                This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

                History
                : 30 September 2021
                Categories
                Article

                Biophysics
                aorta,computational fluid dynamics (cfd),fluid structure interaction (fsi),patient-specific simulation,haemodynamics

                Comments

                Comment on this article