21
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Neurotrophic electrode: method of assembly and implantation into human motor speech cortex.

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The neurotrophic electrode (NE) is designed for longevity and stability of recorded signals. To achieve this aim it induces neurites to grow through its glass tip, thus anchoring it in neuropil. The glass tip contains insulated gold wires for recording the activity of the myelinated neurites that grow into the tip. Neural signals inside the tip are electrically insulated from surrounding neural activity by the glass. The most recent version of the electrode has four wires inside its tip to maximize the number of discriminable signals recorded from ingrown neurites, and has a miniature connector. Flexible coiled, insulated gold wires connect to electronics on the skull that remain subcutaneous. The implanted electronics consist of differential amplifiers, FM transmitters, and a sine wave at power up for tuning and calibration. Inclusion criteria for selecting locked-in subjects include medical stability, normal cognition, and strong caregiver support. The implant target is localized via an fMRI-naming task. Final localization at surgery is achieved by 3D stereotaxic localization. During recording, implanted electronics are powered by magnetic induction across an air gap. Coiled antennas placed on the scalp over the implanted transmitters receive the amplified FM transmitter outputs. Data is processed as described elsewhere where stability and longevity issues are addressed. Five subjects have been successfully implanted with the NE. Recorded signals persisted for over 4 years in two subjects who died from underlying illnesses, and continue for over 3 years in our present subject.

          Related collections

          Author and article information

          Journal
          J Neurosci Methods
          Journal of neuroscience methods
          Elsevier BV
          0165-0270
          0165-0270
          Sep 30 2008
          : 174
          : 2
          Affiliations
          [1 ] Neural Signals Inc., 3400 McClure Bridge Road, Building D, Suite B, Duluth, GA 30096, USA.
          Article
          NIHMS71298 S0165-0270(08)00386-5
          10.1016/j.jneumeth.2008.06.030
          2574508
          18672003
          6bb3b835-ee5f-4711-9b2d-cba525c8c144
          History

          Comments

          Comment on this article