      Determination of toxic elements in coal by ICP-MS after digestion using microwave-induced combustion.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A microwave-induced combustion (MIC) procedure was applied for coal digestion for subsequent determination of As, Cd and Pb by inductively coupled plasma mass spectrometry (ICP-MS) and Hg using cold vapor (CV) generation coupled to ICP-MS. Pellets of coal (500 mg) were combusted using 20 bar of oxygen and ammonium nitrate as aid for ignition. The use of nitric acid as absorbing solution (1.7, 3.5, 5.0, 7.0 and 14 mol L(-1)) was evaluated. For coal samples with higher ash content, better results were found using 7.0 mol L(-1) HNO(3) and an additional reflux step of 5 min after combustion step. For coal samples with ash content lower than 8%, 5.0 mol L(-1) nitric acid was suitable to the absorption of all analytes. Accuracy was evaluated using certified reference material (CRM) of coal and spikes. Agreement with certified values and recoveries was better than 95 and 97%, respectively, for all the analytes. For comparison of results, a procedure recommended by the American Society of Testing and Materials (ASTM) was used. Additionally, a conventional microwave-assisted digestion (MAD) in pressurized vessels was also performed. Using ASTM procedure, analyte losses were observed and a relatively long time was necessary for digestion (>6h). By comparison with MAD procedure, higher sample mass can be digested using MIC allowing better limits of detection. Additionally, the use of concentrated acids was not necessary that is an important aspect in order to obtain low blank levels and lower limits of detection, respectively. The residual carbon content in digests obtained by MAD and MIC was about 15% and <1%, respectively, showing the better digestion efficiency of MIC procedure. Using MIC it was possible to digest completely and simultaneously up to eight samples in only 25 min with relatively lower generation of laboratory effluents.

          Related collections

          Author and article information

          Journal
          Talanta
          Talanta
          Elsevier BV
          1873-3573
          0039-9140
          Dec 15 2010
          : 83
          : 2
          Affiliations
          [1 ] Departamento de Química, Universidade Federal de Santa Maria, 97105-900 Santa Maria, RS, Brazil.
          Article
          S0039-9140(10)00741-1
          10.1016/j.talanta.2010.09.030
          21111147
          6b0d1cda-a9d5-4e77-b69f-a07181b8d5d8
          History

          Comments

          Comment on this article