10
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Digital Workflow for 3D Design and Additive Manufacturing of a New Miniscrew-Supported Appliance for Orthodontic Tooth Movement

      , , , , ,
      Applied Sciences
      MDPI AG

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The introduction of digital workflows and their combination with miniscrew assisted appliances has opened new and enthusiastic perspectives in modern orthodontics. However, in all digital workflows currently in use for orthodontic tooth movement, the miniscrews are inserted first in the maxillary bone, often by means of a surgical guide, and then the appliance is fabricated and secured over the miniscrews with different fixation mechanisms. By doing so, some adaptation problems can be encountered while securing the appliance over the miniscrews, and the chairside time required can therefore be significant. In the present study, we introduce a digital workflow for the design and fabrication of a new appliance, customized on the individual morphology of maxillary bone by using patient Cone Beam Computed Tomography CBCT, for sagittal and vertical orthodontic tooth movement (DIVA, divergent anchors). Differently from the existing protocols, the appliance is cemented first intraorally, serving as a surgical guide for the subsequent insertion of miniscrews. In this way, the adaptation problems are avoided and the chair-side time is reduced.

          Related collections

          Most cited references30

          • Record: found
          • Abstract: not found
          • Article: not found
          Is Open Access

          A Review of 3D Printing Technology for Medical Applications

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Selective laser melting of biocompatible metals for rapid manufacturing of medical parts

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysis.

              Limited evidence is available for the marginal and internal fit of fixed dental restorations fabricated with digital impressions compared with those fabricated with conventional impressions.
                Bookmark

                Author and article information

                Contributors
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                Journal
                ASPCC7
                Applied Sciences
                Applied Sciences
                MDPI AG
                2076-3417
                February 2021
                January 20 2021
                : 11
                : 3
                : 928
                Article
                10.3390/app11030928
                6ab4f4bd-74a6-4f9a-8e0e-8a3af6f5bc20
                © 2021

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article