      Comparison of droplet digital PCR to real-time PCR for quantitative detection of cytomegalovirus.

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Quantitative real-time PCR (QRT-PCR) has been widely implemented for clinical viral load testing, but a lack of standardization and relatively poor precision have hindered its usefulness. Digital PCR offers highly precise, direct quantification without requiring a calibration curve. Performance characteristics of real-time PCR were compared to those of droplet digital PCR (ddPCR) for cytomegalovirus (CMV) load testing. Tenfold serial dilutions of the World Health Organization (WHO) and the National Institute of Standards and Technology (NIST) CMV quantitative standards were tested, together with the AcroMetrix CMV tc panel (Life Technologies, Carlsbad, CA) and 50 human plasma specimens. Each method was evaluated using all three standards for quantitative linearity, lower limit of detection (LOD), and accuracy. Quantitative correlation, mean viral load, and variability were compared. Real-time PCR showed somewhat higher sensitivity than ddPCR (LODs, 3 log(10) versus 4 log(10) copies/ml and IU/ml for NIST and WHO standards, respectively). Both methods showed a high degree of linearity and quantitative correlation for standards (R(2) ≥ 0.98 in each of 6 regression models) and clinical samples (R(2) = 0.93) across their detectable ranges. For higher concentrations, ddPCR showed less variability than QRT-PCR for the WHO standards and AcroMetrix standards (P < 0.05). QRT-PCR showed less variability and greater sensitivity than did ddPCR in clinical samples. Both digital and real-time PCR provide accurate CMV load data over a wide linear dynamic range. Digital PCR may provide an opportunity to reduce the quantitative variability currently seen using real-time PCR, but methods need to be further optimized to match the sensitivity of real-time PCR.

          Related collections

          Author and article information

          Journal
          J Clin Microbiol
          Journal of clinical microbiology
          American Society for Microbiology
          1098-660X
          0095-1137
          Feb 2013
          : 51
          : 2
          Affiliations
          [1 ] Department of Pathology, St Jude Children’s Research Hospital, Memphis, Tennessee, USA. Randall.Hayden@stjude.org
          Article
          JCM.02620-12
          10.1128/JCM.02620-12
          3553899
          23224089
          696629b2-bb0f-426b-b350-258cb9c740b9
          History

          Comments

          Comment on this article