15
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Rapid on-site cytologic evaluation during endobronchial ultrasound-guided transbronchial needle aspiration for nodal staging in patients with lung cancer.

      The Annals of thoracic surgery
      Ultrasonography, Interventional, Biopsy, Fine-Needle, Neoplasm Staging, pathology, Humans, Retrospective Studies, Aged, ultrasonography, Bronchi, Aged, 80 and over, Lung Neoplasms, Adult, Middle Aged, Lymph Nodes, Male, Female

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The utility of rapid on-site evaluation (ROSE) during endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for lymph node staging in lung cancer is still controversial. The aim of this study was to assess the role of ROSE during EBUS-TBNA and the interpretation of its results. We performed a retrospective chart review of patients with suspected or diagnosed lung cancer who underwent EBUS-TBNA for lymph node staging. The slides were air-dried and Diff-Quik (American Scientific Products, McGaw Park, IL) staining was used for ROSE. Additional smears were prepared for Papanicolaou staining and any remaining sample was placed in 10% formalin for histologic evaluation. The results of ROSE were compared with the results of the final pathologic diagnosis. EBUS-TBNA was performed in 438 patients on 965 lymph nodes. Eighty-four lymph nodes (8.7%) were determined insufficient for definitive diagnosis by final cytologic evaluation. However 45 of the 84 lymph nodes were able to be diagnosed by histologic examination. The non-diagnostic sampling rate was 4.0%. There were no false-positive results on ROSE; however 25 cases (5.7%) were falsely evaluated as negative on ROSE. The concordance rate for staging between ROSE and final pathologic diagnosis was 94.3%. The sensitivity, specificity, negative predictive value, and diagnostic accuracy rate of EBUS-TBNA for correct lymph node staging was 96.5%, 100%, 89.8%, and 98.2%, respectively. ROSE during EBUS-TBNA for material adequacy showed a low rate of non-diagnostic sampling. There was a high agreement between the on-site and final pathologic evaluation during EBUS-TBNA; however immediate diagnosis should be approached with caution. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

          Related collections

          Author and article information

          Comments

          Comment on this article

          scite_

          Similar content600

          Cited by25