      Variability in the Clock Face View Description of Femoral Tunnel Placement in ACL Reconstruction Using MRI-Based Bony Models.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Though controversial, the "clock face view" of the intercondylar notch remains a way some surgeons communicate regarding placement of the femoral tunnel in anterior cruciate ligament reconstruction. The purpose of this study was to quantify the differences in angle measurement between several previous descriptions of the clock face view by using a new reference standard. Three-Tesla magnetic resonance imaging (MRI) was used to scan 10 human knees to create three-dimensional MRI-based bony models which were used for measurements. A standardized clock face view was developed with the knee flexed to 90° using the junction of the cartilage and cortex of the medial and lateral surfaces of medial and lateral femoral condyles as the 3 o'clock and 9 o'clock, respectively, with the 12 o'clock established as the midpoint of the roof of the intercondylar notch. With the knee viewed at 90° of flexion, an "idealized" femoral tunnel position was plotted on the medial wall of the lateral femoral condyle at 30° (corresponding to the 10 o'clock or 2 o'clock position). The clock faces as described by Edwards et al, Heming et al, and Mochizuki et al were each then overlaid on this same model and the difference in measurement calculated. The average angles measured when the previously described clock faces were projected onto the idealized clock face view comparing a mark made at 30° were 47.7°, 7.2°, and 49.8° for the methods described by Edwards et al, Heming et al, and Mochizuki et al, respectively (all p < 0.001). Significant variation exists between angle measurements in simulated femoral tunnel placement based on the varying descriptions of the intercondylar clock face.

          Related collections

          Author and article information

          Journal
          J Knee Surg
          The journal of knee surgery
          Georg Thieme Verlag KG
          1938-2480
          1538-8506
          Nov 2018
          : 31
          : 10
          Affiliations
          [1 ] Department of Orthopaedics, Seton Hall-Hackensack Meridian School of Medicine, South Orange, New Jersey.
          [2 ] Baylor Scott and White Orthopaedics at Garland, Garland, Texas.
          [3 ] Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts.
          [4 ] Boston Sports Medicine and Research Institute, Dedham, Massachusetts.
          [5 ] Department of Orthopedics, University of Colorado School of Medicine, Aurora, Colorado.
          Article
          10.1055/s-0038-1626736
          29421839
          66af7ebd-9741-498a-90bc-caa9730a4daa
          History

          Comments

          Comment on this article