2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Study of the Pulse of Peristaltic Pumps for Use in 3D Extrusion Bioprinting

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Peristaltic pumps are used in healthcare for their ability to aseptically displace various fluids, including medium-density gels and suspended solids. However, they have the undesirable characteristic of pulsing at their output. Three-dimensional printing is becoming a reality in tissue engineering, and it generally uses syringes to extrude hydrogels. One of the problems to be solved is the microdosing of biomaterials or bioinks when it is necessary to print large volumes. The use of peristaltic pumps in bioprinting is desirable as it does not limit the volume to the contents of a syringe while achieving dosage control. A peristaltic pump was designed and implemented to avoid pulsation errors and microliter dosing while allowing a large amount of fluid displacement. Two pumps with equal displacement were built. The first uses the conventional profile and is the baseline for comparisons, while the second presents the profile studied and proposed. The concepts demonstrated by Bernoulli were used, fixing the height of a column of water, while the two pumps provide flow to the system asynchronously, allowing the reading of pressure as a function of the speed variation created by the pulsation of each pump. An approximately 100 times reduction in pulsation was observed during fluid displacement with the variance reduced from 2.64 to 0.025 s 2. The two pumps were also installed on a modified Ultimaker FDM 3D printer, and a standard for comparison was printed using a water-based hydrogel, corn starch, and corn-derived triglyceride, showing that the proposed pump improves the deposition quality of the material. Three-dimensional prints, tubes 20 mm in diameter by 8 mm in height and 0.7 mm in wall width, were also produced. Videos obtained show that the first pump was not able to print more than 4 mm in height, while the second prints the model with high quality and without deficiency. The results show that the new pump profile is able to provide a sufficiently constant volume for three-dimensional printing with excellent deposition control, building a simple object but difficult to obtain for a common peristaltic pump.

          Related collections

          Most cited references16

          • Record: found
          • Abstract: not found
          • Article: not found

          Effects of radiation and MHD on compressible Jeffrey fluid with peristalsis

            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            An Integration of a Peristaltic Pump-Based Extruder into a 3D Bioprinter Dedicated to Hydrogels

            The 3D printing technologies used for medical applications are mostly based on paste extruders. These are designed for high capacity, and thus often feature large material reservoirs and large diameter nozzles. A major challenge for most 3D printing platforms is a compromise between speed, accuracy, and/or volume/mass of moving elements. To address these issues, we integrated a peristaltic pump into a bioprinter. That allowed for combining the most important requirements: high precision, a large material reservoir, and safety of biological material. The system of a fully heated nozzle and a cooled print bed were developed to maintain the optimal hydrogel temperature and crosslinking speed. Our modifications of the bioprinter design improved the mechanical properties of the printouts and their accuracy while maintaining the maximal survival rate of cells and increasing the capacity of the bioink reservoir.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Modelling the pulsatile flow rate and pressure response of a roller-type peristaltic pump

                Bookmark

                Author and article information

                Journal
                ACS Omega
                ACS Omega
                ao
                acsodf
                ACS Omega
                American Chemical Society
                2470-1343
                02 July 2022
                19 July 2022
                : 7
                : 28
                : 24091-24101
                Affiliations
                []Graduate Program in Electrical and Computer Engineering, Federal Technologic University of Paraná , Curitiba, Paraná, Brazil
                []Graduate Program in Biomedical Engineering, Federal Technologic University of Paraná , Curitiba, Paraná, Brazil
                Author notes
                Author information
                https://orcid.org/0000-0003-2380-2981
                Article
                10.1021/acsomega.1c07093
                9301694
                35874246
                5f40b8ab-1eaf-4218-8d5a-aaa329b2ef45
                © 2022 The Authors. Published by American Chemical Society

                Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works ( https://creativecommons.org/licenses/by-nc-nd/4.0/).

                History
                Categories
                Article
                Custom metadata
                ao1c07093
                ao1c07093

                Comments

                Comment on this article