          Abstract

          Background

          This study aimed to contrast four different irradiation methods for pediatric medulloblastoma tumors in a dosimetric comparison regarding planning target volume (PTV) coverage and sparing of organs at risk (OARs).

          Methods

          In sum 24 treatment plans for 6 pediatric patients were realized. Besides the clinical standard of a 3D-conformal radiotherapy (3D-CRT) treatment plan taken as a reference, volumetric modulated arc therapy (VMAT) treatment plans (“VMAT_AVD” vs. “noAVD” vs. “FullArc”) were optimized and calculated for each patient. For the thoracic and abdominal region, the short partial-arc VMAT_AVD technique uses an arc setup with reduced arc-length by 100°, using posterior and lateral beam entries. The noAVD uses a half 180° (posterior to lateral directions) and the FullArc uses a full 360° arc setup arrangement. The prescription dose was set to 35.2 Gy.

          Results

          We identified a more conformal dose coverage for PTVs and a better sparing of OARs with used VMAT methods. For VMAT_AVD mean dose reductions in organs at risk can be realized, from 16 to 6.6 Gy, from 27.1 to 8.7 Gy and from 8.0 to 1.9 Gy for the heart, the thyroid and the gonads respectively, compared to the 3D-CRT treatment method. In addition we have found out a superiority of VMAT_AVD compared to the noAVD and FullArc trials with lower exposure to low-dose radiation to the lungs and breasts.

          Conclusions

          With the short partial-arc VMAT_AVD technique, dose exposures to radiosensitive OARS like the heart, the thyroid or the gonads can be reduced and therefore, maybe the occurrence of late sequelae is less likely. Furthermore the PTV conformity is increased. The advantages of the VMAT_AVD have to be weighed against the potentially risks induced by an increased low dose exposure compared to the 3D-CRT method.

          Related collections

          Most cited references49

          • Record: found
          • Abstract: found
          • Article: not found

          Phase III study of craniospinal radiation therapy followed by adjuvant chemotherapy for newly diagnosed average-risk medulloblastoma.

          To determine the event-free survival (EFS) and overall survival of children with average-risk medulloblastoma and treated with reduced-dose craniospinal radiotherapy (CSRT) and one of two postradiotherapy chemotherapies. Four hundred twenty-one patients between 3 years and 21 years of age with nondisseminated medulloblastoma (MB) were prospectively randomly assigned to treatment with 23.4 Gy of CSRT, 55.8 Gy of posterior fossa RT, plus one of two adjuvant chemotherapy regimens: lomustine (CCNU), cisplatin, and vincristine; or cyclophosphamide, cisplatin, and vincristine. Results Forty-two of 421 patients enrolled were excluded from analysis. Sixty-six of the remaining 379 patients had incompletely assessable postoperative studies. Five-year EFS and survival for the cohort of 379 patients was 81% +/- 2.1% and 86% +/- 9%, respectively (median follow-up over 5 years). EFS was unaffected by sex, race, age, treatment regimen, brainstem involvement, or excessive anaplasia. EFS was detrimentally affected by neuroradiographic unassessability. Patients with areas of frank dissemination had a 5-year EFS of 36% +/- 15%. Sixty-seven percent of progressions had some component of dissemination. There were seven second malignancies. Infections occurred more frequently on the cyclophosphamide arm and electrolyte abnormalities were more common on the CCNU regimen. This study discloses an encouraging EFS rate for children with nondisseminated MB treated with reduced-dose craniospinal radiation and chemotherapy. Additional, careful, step-wise reductions in CSRT in adequately staged patients may be possible.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Volumetric modulated arc therapy: a review of current literature and clinical use in practice.

            Volumetric modulated arc therapy (VMAT) is a novel radiation technique, which can achieve highly conformal dose distributions with improved target volume coverage and sparing of normal tissues compared with conventional radiotherapy techniques. VMAT also has the potential to offer additional advantages, such as reduced treatment delivery time compared with conventional static field intensity modulated radiotherapy (IMRT). The clinical worldwide use of VMAT is increasing significantly. Currently the majority of published data on VMAT are limited to planning and feasibility studies, although there is emerging clinical outcome data in several tumour sites. This article aims to discuss the current use of VMAT techniques in practice and review the available data from planning and clinical outcome studies in various tumour sites including prostate, pelvis (lower gastrointestinal, gynaecological), head and neck, thoracic, central nervous system, breast and other tumour sites.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate.

              This article presents a method of quantitative assessment of the degree of conformality and its designation by a single numerical value. A conformation number is introduced to evaluate objectively the degree of conformality. A comparison is made between the conformation number as found for external beam treatment plans and ultrasonically guided 125I seed implants for localized prostate cancer. The conformation number in case of a planning target volume irradiated with two opposed open beams, three open beams, and three beams with customized blocks amounted to 0.17, 0.39, and 0.65, respectively. The conformation number as found for ultrasonically guided permanent prostate implants using 125I seeds averaged 0.72. The conformation number is a convenient instrument for indicating the degree of conformality by a single numerical value. Treatments with a conformation number greater than 0.60 might be termed conformal radiotherapy.
                Bookmark

                Author and article information

                Contributors
                gerhard.pollul@unimedizin-mainz.de
                tilman.bostel@unimedizin-mainz.de
                sascha.grossmann@unimedizin-mainz.de
                sati.akbaba@unimedizin-mainz.de
                heiko.karle@unimedizin-mainz.de
                marcus.stockinger@unimedizin-mainz.de
                heinz.schmidberger@unimedizin-mainz.de
                Journal
                Radiat Oncol
                Radiat Oncol
                Radiation Oncology (London, England)
                BioMed Central (London )
                1748-717X
                5 November 2020
                5 November 2020
                2020
                : 15
                : 256
                Affiliations
                GRID grid.410607.4, Department of Radiation Oncology, , University Medical Center Mainz, ; Langenbeckstraße 1, 55131 Mainz, Germany
                Author information
                http://orcid.org/0000-0003-1992-4687
                Article
                1690
                10.1186/s13014-020-01690-5
                7643335
                33153495
                5db5267e-a9b0-45c6-a393-5ca4316eb277
                © The Author(s) 2020

                Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

                History
                : 10 June 2020
                : 20 October 2020
                Funding
                Funded by: Projekt DEAL
                Categories
                Research
                Custom metadata
                © The Author(s) 2020

                Oncology & Radiotherapy
                pediatric radiation,medulloblastoma,craniospinal irradiation,partial vmat

                Comments

                Comment on this article