Inviting an author to review:
Find an author and click ‘Invite to review selected article’ near their name.
Search for authorsSearch for similar articles
16
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Lumbosacral cerebrospinal fluid volume is the primary determinant of sensory block extent and duration during spinal anesthesia.

      Anesthesiology
      Adult, Anesthesia, Spinal, Cerebrospinal Fluid, physiology, Cerebrospinal Fluid Pressure, Female, Genetic Variation, Humans, Lumbosacral Region, Male

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          BACKGROUND. Injection of local anesthetic into cerebrospinal fluid (CSF) produces anesthesia of unpredictable extent and duration. Although many factors have been identified that affect the extent of spinal anesthesia, correlations are relatively poor and the extent of spread remains unpredictable. This study was designed to determine whether variability in the volume of lumbosacral CSF among individuals is a contributing factor in the variability of spinal anesthesia. Spinal anesthesia was administered to 10 healthy volunteers with 50 mg lidocaine in 7.5% dextrose. The technique was standardized to minimize variability in factors known to affect the distribution of spinal anesthesia. The extent of sensory anesthesia was assessed by pin-prick and by transcutaneous electrical stimulation. Motor blockade was assessed in the quadriceps and gastrocnemius muscles by force dynamometry. Duration of anesthesia was assessed by pinprick, transcutaneous electrical stimulation, and duration of motor blockade. Lumbosacral CSF volumes were calculated from low thoracic, lumbar, and sacral axial magnetic resonance images obtained at 8-mm increments. Volumes of CSF were correlated with measures of extent and duration of spinal anesthesia using the Kendall rank correlation test. Lumbosacral CSF volumes ranged from 42.7 to 81.1 ml. Volumes of CSF correlated with pin-prick assessments of peak sensory block height (P = 0.02) and duration of surgical anesthesia (as assessed by the duration of tolerance to transcutaneous electrical stimulation at the ankle (P < 0.05). Variability in lumbosacral CSF volume is the most important factor identified to date that contributes to the variability in the spread of spinal sensory anesthesia.

          Related collections

          Author and article information

          Journal
          9667290
          10.1097/00000542-199807000-00007

          Chemistry
          Adult,Anesthesia, Spinal,Cerebrospinal Fluid,physiology,Cerebrospinal Fluid Pressure,Female,Genetic Variation,Humans,Lumbosacral Region,Male

          Comments

          Comment on this article

          scite_
          0
          0
          0
          0
          Smart Citations
          0
          0
          0
          0
          Citing PublicationsSupportingMentioningContrasting
          View Citations

          See how this article has been cited at scite.ai

          scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

          Similar content439

          Cited by41