2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Surface Roughness and Color Stability of 3D-Printed Denture Base Materials after Simulated Brushing and Thermocycling.

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Three-dimensional (3D) printing is increasingly used to fabricate denture base materials. However, information on the effect of simulated brushing and thermocycling on the surface roughness and color stability of 3D-printed denture base materials is lacking. The aim of this study was to evaluate the effect of brushing and thermocycling on the surface roughness and color stability of 3D-printed denture base materials and to compare with those of milled and heat-polymerized denture base resins. Disk-shaped specimens (Ø 10 mm × 2 mm) were prepared from 4 different denture base resins (NextDent Denture 3D+ (ND); Denturetec (SC); Polident d.o.o (PD); Promolux (CNV)) (n = 10). Surface roughness (Ra) values were measured before and after polishing with a profilometer. Initial color coordinates were measured by using a spectrophotometer after polishing. Specimens were then consecutively subjected to simulated brushing (10,000 cycles), thermocycling (10,000 cycles), and brushing (10,000 cycles) again. Ra and color coordinates were measured after each interval. Color differences (ΔE00) between each interval were calculated and these values were further evaluated considering previously reported perceptibility (1.72 units) and acceptability (4.08 units) thresholds. Data were analyzed with Friedman, Kruskal-Wallis, and Mann-Whitney U tests (α = 0.05). Ra (p ≥ 0.051) and ΔE00 (p ≥ 0.061) values among different time intervals within each material were similar. Within each time interval, significant differences in Ra (p ≤ 0.002) and ΔE00 values (p ≤ 0.001) were observed among materials. Polishing, brushing, and thermocycling resulted in acceptable surface roughness for all materials that were either similar to or below 0.2 µm. Color of ND printed resin was affected by brushing and thermocycling. All materials had acceptable color stability when reported thresholds are considered.

          Related collections

          Author and article information

          Journal
          Materials (Basel)
          Materials (Basel, Switzerland)
          MDPI AG
          1996-1944
          1996-1944
          Sep 16 2022
          : 15
          : 18
          Affiliations
          [1 ] Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland.
          [2 ] Department of Prevention and Oral Rehabilitation, Universidade Federal de Goiás, Goiânia 74690-900, Goiás, Brazil.
          [3 ] Department of Prosthodontics, Faculty of Dentistry, Eskişehir Osmangazi University, Eskisehir 26040, Turkey.
          [4 ] Translational Medicine Research and Clinical Center, Eskişehir Osmangazi University, Eskisehir 26040, Turkey.
          [5 ] Independent Researcher, Mexico City 03100, Mexico.
          [6 ] Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul 34010, Turkey.
          [7 ] Department of Restorative, Preventive, and Pediatric Dentistry, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland.
          [8 ] Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, OH 43210, USA.
          Article
          ma15186441
          10.3390/ma15186441
          9503686
          36143757
          541a8d5c-1f91-485f-b03d-c75faee8ce00
          History

          thermocycling,surface roughness,denture base,color stability,3D printing

          Comments

          Comment on this article