4
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Detection of macroenzymes: establishing upper reference limits for eight enzymes after polyethylene glycol precipitation

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introduction

          The presence of macroenzymes in blood can cause diagnostic confusion. Therefore, confirming the presence of macroenzymes is important to reduce unnecessary (non-)invasive investigations. Polyethylene glycol (PEG) precipitation is a simple and fast first-line method for the detection of macroenzymes. However, there is no consensus on the upper reference limit for the PEG-precipitable activity (%PPA) of monomeric enzymes. The aim of this study was to verify a PEG precipitation protocol for the detection of macroenzymes in our laboratory by establishing upper reference limits (URLs) and determining imprecision for eight enzymes after PEG precipitation. In addition, we aimed to clinically verify the URLs using samples containing macroenzymes as identified by electrophoresis.

          Materials and methods

          Per enzyme, at least 40 leftover blood samples from adult patients with either normal or increased enzyme activities were diluted 1:1 with 25% PEG 6000 and 1:1 with 0.9% NaCl. Mixtures were incubated for 10 min at 37°C and centrifuged. Supernatant enzyme activity was measured on Cobas c702 and the %PPA was calculated.

          Results

          The following URLs were obtained: 26% PPA for amylase, 29% PPA for alkaline phosphatase (ALP), 61% PPA for alanine aminotransferase, 48% PPA for aspartate aminotransferase, 24% PPA for creatine kinase (CK), 55% PPA for gamma-glutamyltransferase, 65% PPA for lactate dehydrogenase, and 56% PPA for lipase. The within-lab imprecision was < 15%. Regarding the clinical verification, the two historical samples with proven macroCK showed a %PPA of 69% and 43%, respectively, and a sample with proven macroALP had a %PPA of 52%.

          Conclusion

          In this study, URLs for monomeric enzyme activities after PEG precipitation for eight different enzymes were established. The URLs are suitable for clinical use, but are only partially in line with other studies. Therefore, our data highlight the importance of establishing laboratory-specific upper reference limits for %PPA to allow a correct interpretation.

          Related collections

          Most cited references21

          • Record: found
          • Abstract: found
          • Article: not found

          IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C. Part 9: reference procedure for the measurement of catalytic concentration of alkaline phosphatase International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Scientific Division, Committee on Reference Systems of Enzymes (C-RSE) (1)).

          Abstract This paper is the ninth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C and the certification of reference preparations. Other parts deal with: Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes; Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase; Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase; Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase; Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase; Part 6. Reference procedure for the measurement of catalytic concentration of γ-glutamyltransferase; Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase at 37 °C; Part 8. Reference procedure for the measurement of catalytic concentration of α-amylase. The procedure described here is derived from the previously described 30 °C IFCC reference method. Differences are tabulated and commented on in Appendix 1.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase.

            This paper is the fifth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 3.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase.

              This paper is the fourth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 2.
                Bookmark

                Author and article information

                Journal
                Biochem Med (Zagreb)
                Biochem Med (Zagreb)
                BM
                Biochemia Medica
                Croatian Society of Medical Biochemistry and Laboratory Medicine
                1330-0962
                1846-7482
                15 December 2022
                15 February 2023
                : 33
                : 1
                : 010705
                Affiliations
                [1]deptClinical Department of Laboratory Medicine , University Hospitals Leuven , Leuven, Belgium
                Author notes
                [* ]Corresponding author: glynis.frans@ 123456uzleuven.be
                Article
                bm-33-1-010705
                10.11613/BM.2023.010705
                9807236
                36627975
                50daacfd-7012-405d-90ae-935474e3339e
                Croatian Society of Medical Biochemistry and Laboratory Medicine.

                This is an Open Access article distributed under the terms of the Creative Commons Attribution ( http://creativecommons.org/licenses/by/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 27 July 2022
                : 07 November 2022
                Categories
                Original Articles

                precipitation,enzymes,macroamylase,polyethylene glycol,reference value

                Comments