9
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      The Effects of Percutaneous Left Ventricular Assist Device Placement on Native Valve Competency

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references19

          • Record: found
          • Abstract: not found
          • Article: not found

          2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            A prospective, randomized clinical trial of hemodynamic support with Impella 2.5 versus intra-aortic balloon pump in patients undergoing high-risk percutaneous coronary intervention: the PROTECT II study.

            Although coronary artery bypass grafting is generally preferred in symptomatic patients with severe, complex multivessel, or left main disease, some patients present with clinical features that make coronary artery bypass grafting clinically unattractive. Percutaneous coronary intervention with hemodynamic support may be feasible for these patients. Currently, there is no systematic comparative evaluation of hemodynamic support devices for this indication.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              A prospective feasibility trial investigating the use of the Impella 2.5 system in patients undergoing high-risk percutaneous coronary intervention (The PROTECT I Trial): initial U.S. experience.

              We sought to evaluate the safety and feasibility of the Impella 2.5 system (Abiomed Inc., Danvers, Massachusetts) in patients undergoing high-risk percutaneous coronary intervention (PCI). The Impella 2.5 is a miniaturized percutaneous cardiac assist device, which provides up to 2.5 l/min forward flow from the left ventricle into the systemic circulation. In a prospective, multicenter study, 20 patients underwent high-risk PCI with minimally invasive circulatory support employing the Impella 2.5 system. All patients had poor left ventricular function (ejection fraction 10 min). The Impella 2.5 device was implanted successfully in all patients. The mean duration of circulatory support was 1.7 +/- 0.6 h (range: 0.4 to 2.5 h). Mean pump flow during PCI was 2.2 +/- 0.3 l/min. At 30 days, the incidence of major adverse cardiac events was 20% (2 patients had a periprocedural myocardial infarction; 2 patients died at days 12 and 14). There was no evidence of aortic valve injury, cardiac perforation, or limb ischemia. Two patients (10%) developed mild, transient hemolysis without clinical sequelae. None of the patients developed hemodynamic compromise during PCI. The Impella 2.5 system is safe, easy to implant, and provides excellent hemodynamic support during high-risk PCI. (The PROTECT I Trial; NCT00534859).
                Bookmark

                Author and article information

                Journal
                ASAIO Journal
                Ovid Technologies (Wolters Kluwer Health)
                1058-2916
                2022
                August 20 2021
                April 2022
                : 68
                : 4
                : 541-546
                Article
                10.1097/MAT.0000000000001529
                34419983
                4ce78dd9-79af-483c-9537-b86db2ea891b
                © 2022
                History

                Comments

                Comment on this article