      Evaluation of the benefit of the user seal check on N95 filtering facepiece respirator fit.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The objective of this study was to better understand the benefit of the user seal check step for respirator test subjects in the N95 filtering facepiece respirator donning process. To qualify for the study, subjects were required to pass a standard quantitative fit test on at least one of the three N95 filtering facepiece respirator models: 3M 1860 (cup), 3M 1870 (flat-fold), and Kimberly Clark PFR95-270 (duckbill). Eleven subjects were enrolled and performed a series of abbreviated, quantitative fit tests where they were randomly asked either to perform or not perform a user seal check with 20 different respirator samples of each model. The experimental design included 3 respirator models × 10 subjects × 2 treatment levels with 10 replications. Geometric mean (GM) fit factors and percentages of times a fit factor ≥ 100 was achieved for a donning were compared for each subject with and without the user seal check across all models and for each model. Higher GM fit factors and smaller geometric standard deviations across all models were achieved for 10 of the 11 subjects when performing a user seal check compared with not performing a user seal check. Geometric mean fit factors of 148, 184, and 156, compared with 126, 187, and 115, respectively, were obtained for the 3M 1860, 3M 1870, and Kimberly Clark PFR95-270 models when the user seal check was performed vs. not performed. Differences in the GM fit factors for the 3M 1860 and Kimberly Clark PFR95-270 models were statistically significant (p < 0.05) when performing a user seal check vs. not performing a user seal check. These data suggest that there may be some benefit to performing the user seal check for at least some models during the filtering facepiece respirator donning process for workers who have previously passed a fit test for those respirator models. Additional research is needed with larger groups of subjects and respirator models/types.

          Related collections

          Author and article information

          Journal
          J Occup Environ Hyg
          Journal of occupational and environmental hygiene
          Informa UK Limited
          1545-9632
          1545-9624
          2012
          : 9
          : 6
          Affiliations
          [1 ] National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, Pennsylvania 15236, USA.
          Article
          10.1080/15459624.2012.683757
          22606976
          4720d40a-fc6e-4584-a597-2eea923d3443
          History

          Comments

          Comment on this article

          scite_
          0
          0
          0
          0
          Smart Citations
          0
          0
          0
          0
          Citing PublicationsSupportingMentioningContrasting
          View Citations

          See how this article has been cited at scite.ai

          scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

          Similar content336

          Cited by12