          Abstract

          The Gram-negative bacterium, Salmonella Typhimurium (S. Typhimurium) is a food borne pathogen responsible for numerous hospitalisations and deaths all over the world. Conventional detection methods for pathogens are time consuming and labour-intensive. Hence, there is considerable interest in faster and simpler detection methods. Polypyrrole-based polymers, due to their intrinsic chemical and electrical properties, have been demonstrated to be valuable candidates for the fabrication of chemo/biosensors and functional surfaces. Similarly aptamers have been shown to be good alternatives to antibodies in the development of affinity biosensors. In this study, we report on the combination of poly [pyrrole-co-3-carboxyl-pyrrole] copolymer and aptamer for the development of a label-less electrochemical biosensor suitable for the detection of S. Typhimurium. Impedimetric measurements were facilitated by the effect of the aptamer/target interaction on the intrinsic conjugation of the poly [pyrrole-co-3-carboxyl-pyrrole] copolymer and subsequently on its electrical properties. The aptasensor detected S. Typhimurium in the concentration range 10(2)-10(8) CFU mL(-1) with high selectivity over other model pathogens and with a limit of quantification (LOQ) of 100 CFU mL(-1) and a limit of detection (LOD) of 3 CFU mL(-1). The suitability of the aptasensor for real sample detection was demonstrated via recovery studies performed in spiked apple juice samples. We envisage this to be a viable approach for the inexpensive and rapid detection of pathogens in food, and possibly in other environmental samples.

          Related collections

          Author and article information

          Journal
          Biosens Bioelectron
          Biosensors & bioelectronics
          Elsevier BV
          1873-4235
          0956-5663
          Jun 15 2016
          : 80
          Affiliations
          [1 ] Biosensors & Bioelectronics Centre, Dept. of Physics, Chemistry and Biology (IFM), Linköping University, Linköping, Sweden; Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, Mashhad, Iran.
          [2 ] Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, Mashhad, Iran.
          [3 ] Biosensors & Bioelectronics Centre, Dept. of Physics, Chemistry and Biology (IFM), Linköping University, Linköping, Sweden.
          [4 ] Biosensors & Bioelectronics Centre, Dept. of Physics, Chemistry and Biology (IFM), Linköping University, Linköping, Sweden. Electronic address: valerio.beni@acreo.se.
          Article
          S0956-5663(16)30057-4
          10.1016/j.bios.2016.01.057
          26836649
          3d34af82-4810-4dcc-bd58-2fbb8a746059
          Copyright © 2016 Elsevier B.V. All rights reserved.
          History

          Aptamer,Electrochemical impedance spectroscopy,Label-free detection,Poly [pyrrole-co-3-carboxyl-pyrrole],S. Typhimurium

          Comments

          Comment on this article