10
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found

      Predicting Fluid Responsiveness in Children : A Systematic Review

      , , ,
      Anesthesia & Analgesia
      Ovid Technologies (Wolters Kluwer Health)

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Administration of fluid to improve cardiac output is the mainstay of hemodynamic resuscitation. Not all patients respond to fluid therapy, and excessive fluid administration is harmful. Predicting fluid responsiveness can be challenging, particularly in children. Numerous hemodynamic variables have been proposed as predictors of fluid responsiveness. Dynamic variables based on the heart-lung interaction appear to be excellent predictors of fluid responsiveness in adults, but there is no consensus on their usefulness in children.

          Related collections

          Most cited references50

          • Record: found
          • Abstract: not found
          • Article: not found

          Bias in meta-analysis detected by a simple, graphical test

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature.

            : A systematic review of the literature to determine the ability of dynamic changes in arterial waveform-derived variables to predict fluid responsiveness and compare these with static indices of fluid responsiveness. The assessment of a patient's intravascular volume is one of the most difficult tasks in critical care medicine. Conventional static hemodynamic variables have proven unreliable as predictors of volume responsiveness. Dynamic changes in systolic pressure, pulse pressure, and stroke volume in patients undergoing mechanical ventilation have emerged as useful techniques to assess volume responsiveness. : MEDLINE, EMBASE, Cochrane Register of Controlled Trials and citation review of relevant primary and review articles. : Clinical studies that evaluated the association between stroke volume variation, pulse pressure variation, and/or stroke volume variation and the change in stroke volume/cardiac index after a fluid or positive end-expiratory pressure challenge. : Data were abstracted on study design, study size, study setting, patient population, and the correlation coefficient and/or receiver operating characteristic between the baseline systolic pressure variation, stroke volume variation, and/or pulse pressure variation and the change in stroke index/cardiac index after a fluid challenge. When reported, the receiver operating characteristic of the central venous pressure, global end-diastolic volume index, and left ventricular end-diastolic area index were also recorded. Meta-analytic techniques were used to summarize the data. Twenty-nine studies (which enrolled 685 patients) met our inclusion criteria. Overall, 56% of patients responded to a fluid challenge. The pooled correlation coefficients between the baseline pulse pressure variation, stroke volume variation, systolic pressure variation, and the change in stroke/cardiac index were 0.78, 0.72, and 0.72, respectively. The area under the receiver operating characteristic curves were 0.94, 0.84, and 0.86, respectively, compared with 0.55 for the central venous pressure, 0.56 for the global end-diastolic volume index, and 0.64 for the left ventricular end-diastolic area index. The mean threshold values were 12.5 +/- 1.6% for the pulse pressure variation and 11.6 +/- 1.9% for the stroke volume variation. The sensitivity, specificity, and diagnostic odds ratio were 0.89, 0.88, and 59.86 for the pulse pressure variation and 0.82, 0.86, and 27.34 for the stroke volume variation, respectively. : Dynamic changes of arterial waveform-derived variables during mechanical ventilation are highly accurate in predicting volume responsiveness in critically ill patients with an accuracy greater than that of traditional static indices of volume responsiveness. This technique, however, is limited to patients who receive controlled ventilation and who are not breathing spontaneously.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure.

              In mechanically ventilated patients with acute circulatory failure related to sepsis, we investigated whether the respiratory changes in arterial pressure could be related to the effects of volume expansion (VE) on cardiac index (CI). Forty patients instrumented with indwelling systemic and pulmonary artery catheters were studied before and after VE. Maximal and minimal values of pulse pressure (Pp(max) and Pp(min)) and systolic pressure (Ps(max) and Ps(min)) were determined over one respiratory cycle. The respiratory changes in pulse pressure (DeltaPp) were calculated as the difference between Pp(max) and Pp(min) divided by the mean of the two values and were expressed as a percentage. The respiratory changes in systolic pressure (DeltaPs) were calculated using a similar formula. The VE-induced increase in CI was >/= 15% in 16 patients (responders) and < 15% in 24 patients (nonresponders). Before VE, DeltaPp (24 +/- 9 versus 7 +/- 3%, p < 0.001) and DeltaPs (15 +/- 5 versus 6 +/- 3%, p < 0.001) were higher in responders than in nonresponders. Receiver operating characteristic (ROC) curves analysis showed that DeltaPp was a more accurate indicator of fluid responsiveness than DeltaPs. Before VE, a DeltaPp value of 13% allowed discrimination between responders and nonresponders with a sensitivity of 94% and a specificity of 96%. VE-induced changes in CI closely correlated with DeltaPp before volume expansion (r(2) = 0. 85, p < 0.001). VE decreased DeltaPp from 14 +/- 10 to 7 +/- 5% (p < 0.001) and VE-induced changes in DeltaPp correlated with VE-induced changes in CI (r(2) = 0.72, p < 0.001). It was concluded that in mechanically ventilated patients with acute circulatory failure related to sepsis, analysis of DeltaPp is a simple method for predicting and assessing the hemodynamic effects of VE, and that DeltaPp is a more reliable indicator of fluid responsiveness than DeltaPs.
                Bookmark

                Author and article information

                Journal
                Anesthesia & Analgesia
                Ovid Technologies (Wolters Kluwer Health)
                0003-2999
                2013
                December 2013
                : 117
                : 6
                : 1380-1392
                Article
                10.1213/ANE.0b013e3182a9557e
                24257389
                3d1190a0-e9b8-4ef6-b0e0-9c6c29068b53
                © 2013
                History

                Comments

                Comment on this article