      Refractive outcome and tomographic changes after Descemet membrane endothelial keratoplasty in pseudophakic eyes with Fuchs’ endothelial dystrophy

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          To analyze refractive and topographic changes secondary to Descemet membrane endothelial keratoplasty (DMEK) in pseudophakic eyes with Fuchs’ endothelial dystrophy (FED).

          Methods

          Eighty-seven pseudophakic eyes of 74 patients who underwent subsequent DMEK surgery for corneal endothelial decompensation and associated visual impairment were included. Median post-operative follow-up time was 12 months (range: 3–26 months). Main outcome measures were pre- and post-operative manifest refraction, anterior and posterior corneal astigmatism, simulated keratometry (CA SimK) and Q value obtained by Scheimpflug imaging. Secondary outcome measures included corrected distance visual acuity (CDVA), central corneal densitometry, central corneal thickness, corneal volume (CV), anterior chamber volume (ACV) and anterior chamber depth (ACD).

          Results

          After DMEK surgery, mean pre-operative spherical equivalent (± SD) changed from + 0.04 ± 1.73 D to + 0.37 ± 1.30 D post-operatively ( p = 0.06). CDVA, proportion of emmetropic eyes, ACV and ACD increased significantly during follow-up. There was also a significant decrease in posterior corneal astigmatism, central corneal densitometry, central corneal thickness and corneal volume over time ( p = 0.001). Only anterior corneal astigmatism and simulated keratometry (CA SimK) remained fairly stable after DMEK.

          Conclusion

          Despite tendencies toward a hyperopic shift, changes in SE were not significant and refraction remained overall stable in pseudophakic patients undergoing DMEK for FED. Analysis of corneal parameters by Scheimpflug imaging mainly revealed changes in posterior corneal astigmatism pointing out the relevance of posterior corneal profile changes during edema resolution after DMEK.

          Related collections

          Most cited references24

          • Record: found
          • Abstract: found
          • Article: not found

          Descemet membrane endothelial keratoplasty (DMEK).

          To describe Descemet membrane endothelial keratoplasty (DMEK) with organ cultured Descemet membrane (DM) in a human cadaver eye model and a patient with Fuchs endothelial dystrophy. In 10 human cadaver eyes and 1 patient eye, a 3.5-mm clear corneal tunnel incision was made. The anterior chamber was filled with air, and the DM was stripped off from the posterior stroma. From organ-cultured donor corneo-scleral rims, 9.0-mm-diameter "DM rolls" were harvested. Each donor DM roll was inserted into a recipient anterior chamber, positioned onto the posterior stroma, and kept in position by completely filling the anterior chamber with air for 30 minutes. In all recipient eyes, the donor DM maintained its position after a 30-minute air-fill of the anterior chamber followed by an air-liquid exchange. In the patient's eye, 1 week after transplantation, best-corrected visual acuity was 1.0 (20/20) with the patient's preoperative refraction, and the endothelial cell density averaged 2350 cells/mm. DMEK may provide quick visual rehabilitation in the treatment of corneal endothelial disorders by transplantation of an organ-cultured DM transplanted through a clear corneal tunnel incision. DMEK may be a highly accessible procedure to corneal surgeons, because donor DM sheets can be prepared from preserved corneo-scleral rims.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Descemet Membrane Endothelial Keratoplasty: Safety and Outcomes

            To review the published literature on the safety and outcomes of Descemet membrane endothelial keratoplasty (DMEK) for the surgical treatment of corneal endothelial dysfunction.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Correcting astigmatism with toric intraocular lenses: effect of posterior corneal astigmatism.

              To evaluate the impact of posterior corneal astigmatism on outcomes with toric intraocular lenses (IOLs). Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Case series. Corneal astigmatism was measured using 5 devices before and 3 weeks after cataract surgery. Toric IOL alignment was recorded at surgery and at the slitlamp 3 weeks postoperatively. The actual corneal astigmatism was calculated based on refractive astigmatism 3 weeks postoperatively and the effective toric power calculated with the Holladay 2 formula. The prediction error was calculated as the difference between the astigmatism measured by each device and the actual corneal astigmatism. Vector analysis was used in all calculations. With the IOLMaster, Lenstar, Atlas, manual keratometer, and Galilei (combined Placido-dual Scheimpflug analyzer), the mean prediction errors (D) were, respectively, 0.59 @ 89.7, 0.48 @ 91.2, 0.51 @ 78.7, 0.62 @ 97.2, and 0.57 @ 93.9 for with-the-rule (WTR) astigmatism (60 to 120 degrees), and 0.17 @ 86.2, 0.23 @ 77.7, 0.23 @ 91.4, 0.41 @ 58.4, and 0.12 @ 7.3 for against-the-rule (ATR) astigmatism (0 to 30 degrees and 150 to 180 degrees). In the WTR eyes, there were significant WTR prediction errors (0.5 to 0.6 diopters [D]) by all devices. In ATR eyes, WTR prediction errors were 0.2 to 0.3 D by all devices except the Placido-dual Scheimpflug analyzer (all P<.05 with Bonferroni correction). Corneal astigmatism was overestimated in WTR by all devices and underestimated in ATR by all except the Placido-dual Scheimpflug analyzer. A new toric IOL nomogram is proposed. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
                Bookmark

                Author and article information

                Contributors
                kohnen@em.uni-frankfurt.de
                Journal
                Int Ophthalmol
                Int Ophthalmol
                International Ophthalmology
                Springer Netherlands (Dordrecht )
                0165-5701
                1573-2630
                29 June 2021
                29 June 2021
                2021
                : 41
                : 8
                : 2897-2904
                Affiliations
                [1 ]GRID grid.7839.5, ISNI 0000 0004 1936 9721, Department of Ophthalmology, , Goethe-University, ; Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
                [2 ]GRID grid.15276.37, ISNI 0000 0004 1936 8091, Department of Ophthalmology, , University of Florida, ; Gainesville, USA
                Author information
                http://orcid.org/0000-0002-6933-9585
                Article
                1850
                10.1007/s10792-021-01850-w
                8289766
                34189706
                3bd6468d-b2ec-4ad1-99b3-86338d0e9c17
                © The Author(s) 2021

                Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 16 December 2020
                : 8 April 2021
                Funding
                Funded by: Johann Wolfgang Goethe-Universität, Frankfurt am Main (1022)
                Categories
                Original Paper
                Custom metadata
                © Springer Nature B.V. 2021

                Ophthalmology & Optometry
                dmek,refractive changes,corneal tomography,pseudophakia
                Ophthalmology & Optometry
                dmek, refractive changes, corneal tomography, pseudophakia

                Comments

                Comment on this article