      Intrasynovial flexor tendon repair: a biomechanical study of variations in suture application in human cadavera.

      Journal of Orthopaedic Research
      Aged, Aged, 80 and over, Biomechanical Phenomena, Female, Hand, surgery, Hand Injuries, Humans, Male, Suture Techniques, Tendon Injuries, Tendons

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To improve the functional outcomes of intrasynovial tendon suture, prior experiments evaluated individual technical modifications used in the repair process. Few studies, however, have assessed the combinatorial effects of those suture modifications in an integrated biomechanical manner, including a sample size sufficient to make definitive observations on repair technique. Two hundred fifty-six flexor tendon repairs were performed in human cadavera, and biomechanical properties were determined. The effects of five factors for flexor tendon repair were tested: core suture caliber (4-0 or 3-0), number of sutures crossing the repair site (four- or eight-strand), core suture purchase (0.75 or 1.2 cm), peripheral suture caliber (6-0 or 5-0), and peripheral suture purchase (superficial or 2 mm). Significant factors affecting the properties of the repair were the number of core suture strands and the peripheral suture purchase. The least significant factors were core suture purchase and peripheral suture caliber. The choice of core suture caliber affected the properties of repair marginally. Based on these results, we recommend that surgeons continue to focus on multi-strand repair methods, as the properties of eight-strand repairs were far better than those of four-strand repairs. To resist gap formation and enhance repair strength, a peripheral suture with 2 mm purchase is also recommended. Finally, since core suture caliber affected some biomechanical properties, including the failure mode, a 3-0 suture could be considered, provided that future in vivo studies can confirm that gliding properties are not adversely influenced. Copyright © 2012 Orthopaedic Research Society.

          Related collections

          Author and article information

          Journal
          22457145
          3621034
          10.1002/jor.22108

          Chemistry
          Aged,Aged, 80 and over,Biomechanical Phenomena,Female,Hand,surgery,Hand Injuries,Humans,Male,Suture Techniques,Tendon Injuries,Tendons

          Comments

          Comment on this article