      A direct comparison of wet, dry and insulating bioelectric recording electrodes

      ,
      Physiological Measurement
      IOP Publishing

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Alternatives to conventional wet electrode types are keenly sought for biomedical use and physiological research, especially when prolonged recording of biosignals is demanded. This paper describes a quantitative comparison of three types of bioelectrode (wet, dry and insulating) based on tests involving electrode impedance, static interference and motion artefact induced by various means. Data were collected simultaneously, and in the same physical environment for all electrode types. Results indicate that in many situations the performance of dry and insulating electrodes compares favourably with wet electrodes. The influence of non-stationary electric fields on shielded dry and insulating electrode types was compared to wet types. It was observed that interference experienced by dry and insulating electrode types was 40 dB and 34 dB less than that experienced by wet electrode types. Similarly, the effect of motion artefact on dry and insulating electrodes was compared to wet types. Artefact levels for dry and insulating electrodes were significantly higher than those for wet types at the beginning of trials conducted. By the end of the trial periods artefact levels for dry and insulating types were lower than wet electrodes by an average of 8.2 dB and 6.8 dB respectively. The reservations expressed in other studies regarding the viability of dry and insulating electrodes for reliable sensing of biosignals are not supported by the work described here.

          Related collections

          Most cited references25

          • Record: found
          • Abstract: not found
          • Article: not found

          Reducing motion artifacts and interference in biopotential recording.

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            A dry electrode for EEG recording

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              The origin of skin-stretch-caused motion artifacts under electrodes

                Bookmark

                Author and article information

                Journal
                Physiological Measurement
                Physiol. Meas.
                IOP Publishing
                0967-3334
                1361-6579
                May 01 2000
                May 01 2000
                May 11 2000
                : 21
                : 2
                : 271-283
                Article
                10.1088/0967-3334/21/2/307
                10847194
                39973648-75ec-4ec6-8cfd-9d2e9116f081
                © 2000
                History

                Comments

                Comment on this article