      Endovascular stents for coarctation of the aorta: initial results and intermediate-term follow-up

      , , ,
      Journal of the American College of Cardiology
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The aim of this study was to evaluate the use of endovascular stents in native and recurrent coarctation of the aorta (CoA). Stents have been used successfully in various locations. Their use in CoA can be an alternative to surgery or balloon angioplasty (BA). Thirty-four patients with CoA (13 native and 21 re-coarctation after surgery or BA) with a mean age of 16 +/- 8 years (range 4 to 36 years) underwent attempted stent implantation between 1993 and 1999. Successful outcome was defined as peak systolic pressure gradient after stent implantation < 20 mm Hg. Stents were implanted in 33/34 patients, and successful outcome occurred in 32/33 patients. Peak systolic pressure gradient decreased from 32 +/- 12 mm Hg to 4 +/- 11 mm Hg (p < 0.001). Coarctation site to descending aorta diameter ratio increased from 0.46 +/- 0.16 to 0.92 +/- 0.16 (p < 0.001). Two patients underwent successful stent re-dilation 16 and 21 months after initial implantation. Six patients (18%) developed complications, including two patients who underwent surgery. Follow-up for 29 +/- 17 months (range: 5 to 81 months) demonstrated no evidence of re-coarctation, aneurysm formation, stent displacement or fracture. Systolic blood pressure (SBP) decreased from 136 +/- 21 mm Hg before stent placement to 122 +/- 19 mm Hg at follow-up (p = 0.002). The SBP gradient decreased from 39 +/- 18 mm Hg to 4 +/- 6 mm Hg, and peak Doppler gradient decreased from 51 +/- 26 mm Hg to 13 +/- 11 mm Hg at follow-up (p < 0.001). Intravascular stent placement for native and recurrent CoA has excellent results in the short and intermediate terms. Long-term outcome remains to be evaluated.

          Related collections

          Author and article information

          Journal
          Journal of the American College of Cardiology
          Journal of the American College of Cardiology
          Elsevier BV
          07351097
          November 2001
          November 2001
          : 38
          : 5
          : 1518-1523
          Article
          10.1016/S0735-1097(01)01572-8
          11691533
          38f63368-692c-4a87-88ae-ee8a8b650936
          © 2001

          https://www.elsevier.com/tdm/userlicense/1.0/

          https://www.elsevier.com/open-access/userlicense/1.0/

          History

          Comments

          Comment on this article