3
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Objective recognition of cough sound as biomarker for aerial pollutants

      ,
      Indoor Air
      Wiley

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references23

          • Record: found
          • Abstract: found
          • Article: not found

          The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity.

          Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity were studied in a normally furnished office space (108 m3) ventilated with an outdoor airflow of 3, 10 or 30 L/s per person, corresponding to an air change rate of 0.6, 2 or 6 h-1. The temperature of 22 degrees C, the relative humidity of 40% and all other environmental parameters remained unchanged. Five groups of six female subjects were each exposed to the three ventilation rates, one group and one ventilation rate at a time. Each exposure lasted 4.6 h and took place in the afternoon. Subjects were unaware of the intervention and remained thermally neutral by adjusting their clothing. They assessed perceived air quality and SBS symptoms at intervals, and performed simulated normal office work. Increasing ventilation decreased the percentage of subjects dissatisfied with the air quality (P < 0.002) and the intensity of odour (P < 0.02), and increased the perceived freshness of air (P < 0.05). It also decreased the sensation of dryness of mouth and throat (P < 0.0006), eased difficulty in thinking clearly (P < 0.001) and made subjects feel generally better (P < 0.0001). The performance of four simulated office tasks improved monotonically with increasing ventilation rates, and the effect reached formal significance in the case of text-typing (P < 0.03). For each two-fold increase in ventilation rate, performance improved on average by 1.7%. This study shows the benefits for health, comfort and productivity of ventilation at rates well above the minimum levels prescribed in existing standards and guidelines. It confirms the results of a previous study in the same office when the indoor air quality was improved by decreasing the pollution load while the ventilation remained unchanged.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Long-term ambient air pollution and respiratory symptoms in adults (SAPALDIA study). The SAPALDIA Team.

            The association between long-term exposure to ambient air pollution and respiratory symptoms was investigated in a cross-sectional study in random population samples of adults (aged 18 to 60 yr, n = 9,651) at eight study sites in Switzerland. Information on respiratory symptoms was obtained with an extended version of the European Community Respiratory Health Survey questionnaire. The impact of annual mean concentrations of air pollutants was analyzed separately for never-, former, and current smokers. After controlling for age, body mass index, gender, parental asthma, parental atopy, low education, and foreign citizenship, we found positive associations between annual mean concentrations of NO2, total suspended particulates, and particulates of less than 10 micrometers in aerodynamic diameter (PM10) and reported prevalences of chronic phlegm production, chronic cough or phlegm production, breathlessness at rest during the day, breathlessness during the day or at night, and dyspnea on exertion. We found no associations with wheezing without cold, current asthma, chest tightness, or chronic cough. Among never-smokers, the odds ratio (95% confidence interval) for a 10 micrograms/ m3 increase in the annual mean concentration of PM10 was 1. 35 (1.11 to 1.65) for chronic phlegm production, 1.27 (1.08 to 1.50) for chronic cough or phlegm production, 1.48 (1.23 to 1.78) for breathlessness during the day, 1.33 (1.14 to 1.55) for breathlessness during the day or at night, and 1.32 (1.18 to 1.46) for dyspnea on exertion. No associations were found with annual mean concentrations of O3. Similar associations were also found for former and current smokers, except for chronic phlegm production. The observed associations remained stable when further control was applied for environmental tobacco smoke exposure, past and current occupational exposures, atopy, and early childhood respiratory infections when restricting the analysis to long-term residents and to non- alpine areas, and when excluding subjects with physician-diagnosed asthma. The high correlation between the pollutants makes it difficult to sort out the effect of one single pollutant. This study provides further evidence that long-term exposure to air pollution of rather low levels is associated with higher prevalences of respiratory symptoms in adults.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Airways inflammation among workers in a paper industry.

              Exposure to organic dusts may cause airways inflammation in a large proportion of exposed persons. Most studies have relied on questionnaires and spirometry for diagnosis. To assess the possibility of determining the presence of inflammation using clinical diagnostic procedures, a study was undertaken among workers in a paper industry. Participants were 83 workers and 44 controls. Airborne endotoxin and (1-->3)-beta-D-glucan levels at the worksites were determined. The effects of this exposure were evaluated using a questionnaire, spirometry and measurements of airway responsiveness (methacholine) and levels of eosinophil cationic protein (ECP), myeloperoxidase (MPO), and C-reactive protein (CRP) in serum. The workers had a decreased baseline forced expiratory volume in one second (FEV1) and an increased airway responsiveness compared with controls. The concentrations of ECP and MPO were elevated compared with controls. There was a relation between exposure to endotoxin and (1-->3)-beta-D-glucan and airway responsiveness as well as ECP levels, when controlling for age, sex, smoking habits, atopy and asthma. The results suggest an increased prevalence of subjective respiratory symptoms, and an increased airway responsiveness among exposed workers. There was also a relationship between the serum concentration of eosinophil cationic protein and airway responsiveness. Taken together, the results suggest the presence of airways inflammation in the workers.
                Bookmark

                Author and article information

                Journal
                Indoor Air
                Indoor Air
                Wiley
                0905-6947
                1600-0668
                February 2004
                February 2004
                : 14
                : 1
                : 10-15
                Article
                10.1046/j.1600-0668.2003.00195.x
                3633f19a-9455-4514-bfef-22460b689049
                © 2004

                http://doi.wiley.com/10.1002/tdm_license_1.1

                History

                Comments

                Comment on this article