30
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Immune monitoring using mass cytometry and related high-dimensional imaging approaches

      ,
      Nature Reviews Rheumatology
      Springer Science and Business Media LLC

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The cellular complexity and functional diversity of the human immune system necessitate the use of high-dimensional single-cell tools to uncover its role in multifaceted diseases such as rheumatic diseases, as well as other autoimmune and inflammatory disorders. Proteomic technologies that use elemental (heavy metal) reporter ions, such as mass cytometry (also known as CyTOF) and analogous high-dimensional imaging approaches (including multiplexed ion beam imaging (MIBI) and imaging mass cytometry (IMC)), have been developed from their low-dimensional counterparts, flow cytometry and immunohistochemistry, to meet this need. A growing number of studies have been published that use these technologies to identify functional biomarkers and therapeutic targets in rheumatic diseases, but the full potential of their application to rheumatic disease research has yet to be fulfilled. This Review introduces the underlying technologies for high-dimensional immune monitoring and discusses aspects necessary for their successful implementation, including study design principles, analytical tools and future developments for the field of rheumatology.

          Related collections

          Most cited references105

          • Record: found
          • Abstract: found
          • Article: not found

          Standardizing immunophenotyping for the Human Immunology Project.

          The heterogeneity in the healthy human immune system, and the immunological changes that portend various diseases, have been only partially described. Their comprehensive elucidation has been termed the 'Human Immunology Project'. The accurate measurement of variations in the human immune system requires precise and standardized assays to distinguish true biological changes from technical artefacts. Thus, to be successful, the Human Immunology Project will require standardized assays for immunophenotyping humans in health and disease. A major tool in this effort is flow cytometry, which remains highly variable with regard to sample handling, reagents, instrument setup and data analysis. In this Review, we outline the current state of standardization of flow cytometry assays and summarize the steps that are required to enable the Human Immunology Project.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Mass cytometry: technique for real time single cell multitarget immunoassay based on inductively coupled plasma time-of-flight mass spectrometry.

            A novel instrument for real time analysis of individual biological cells or other microparticles is described. The instrument is based on inductively coupled plasma time-of-flight mass spectrometry and comprises a three-aperture plasma-vacuum interface, a dc quadrupole turning optics for decoupling ions from neutral components, an rf quadrupole ion guide discriminating against low-mass dominant plasma ions, a point-to-parallel focusing dc quadrupole doublet, an orthogonal acceleration reflectron analyzer, a discrete dynode fast ion detector, and an 8-bit 1 GHz digitizer. A high spectrum generation frequency of 76.8 kHz provides capability for collecting multiple spectra from each particle-induced transient ion cloud, typically of 200-300 micros duration. It is shown that the transients can be resolved and characterized individually at a peak frequency of 1100 particles per second. Design considerations and optimization data are presented. The figures of merit of the instrument are measured under standard inductively coupled plasma (ICP) operating conditions ( 900 for m/z = 159, the sensitivity with a standard sample introduction system of >1.4 x 10(8) ion counts per second per mg L(-1) of Tb and an abundance sensitivity of (6 x 10(-4))-(1.4 x 10(-3)) (trailing and leading masses, respectively) are shown. The mass range (m/z = 125-215) and abundance sensitivity are sufficient for elemental immunoassay with up to 60 distinct available elemental tags. When 500) can be used, which provides >2.4 x 10(8) cps per mg L(-1) of Tb, at (1.5 x 10(-3))-(5.0 x 10(-3)) abundance sensitivity. The real-time simultaneous detection of multiple isotopes from individual 1.8 microm polystyrene beads labeled with lanthanides is shown. A real time single cell 20 antigen expression assay of model cell lines and leukemia patient samples immuno-labeled with lanthanide-tagged antibodies is presented.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Extracting a Cellular Hierarchy from High-dimensional Cytometry Data with SPADE

              Multiparametric single-cell analysis is critical for understanding cellular heterogeneity. Despite recent technological advances in single-cell measurements, methods for analyzing high-dimensional single-cell data are often subjective, labor intensive and require prior knowledge of the biological system under investigation. To objectively uncover cellular heterogeneity from single-cell measurements, we present a novel computational approach, Spanning-tree Progression Analysis of Density-normalized Events (SPADE). We applied SPADE to cytometry data of mouse and human bone marrow. In both cases, SPADE organized cells in a hierarchy of related phenotypes that partially recapitulated well-described patterns of hematopoiesis. In addition, SPADE produced a map of intracellular signal activation across the landscape of human hematopoietic development. SPADE revealed a functionally distinct cell population, natural killer (NK) cells, without using any NK-specific parameters. SPADE is a versatile method that facilitates the analysis of cellular heterogeneity, the identification of cell types, and comparison of functional markers in response to perturbations.
                Bookmark

                Author and article information

                Journal
                Nature Reviews Rheumatology
                Nat Rev Rheumatol
                Springer Science and Business Media LLC
                1759-4790
                1759-4804
                December 31 2019
                Article
                10.1038/s41584-019-0338-z
                7232872
                31892734
                338ce582-1788-4049-9955-61f5cd15fbb8
                © 2019

                http://www.springer.com/tdm

                History

                Comments

                Comment on this article