      Impedance-Based Neutralizing Antibody Detection Biosensor with Application in SARS-CoV-2 Infection

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Although safe and efficacious coronavirus disease-2019 (COVID-19) vaccines are available, real protective immunity is revealed by the serum COVID-19 neutralizing antibody (NAb) concentration. NAbs deactivate the virus by attaching to the viral receptor-binding domain (RBD), which interacts with angiotensin-converting enzyme 2 (ACE2) on the human cell. This paper introduces inexpensive, rapid, sensitive, and quantifiable impedance-based immunosensors to evaluate the NAb. The sensor limit of detection is experimentally determined in different buffer dilutions using bovine IgG–anti-bovine IgG interaction. The dominance of AC electrokinetic transport and molecular diffusion in the sensor is investigated using scaling analysis and numerical simulations. The results demonstrated that the sensor detection mechanism is mainly based on the diffusion of the biomolecules onto the electrode surface. After evaluating the sensor working principles, viral RBD buffers, including different NAb concentrations, are applied to the sensor, immobilized with the human ACE2 (hACE2). Results demonstrate that the sensor is capable of NAb detection in the analytical measuring interval between 45 ng/mL and 185 ng/mL. Since the present sensor provides fast test results with lower costs, it can be used to assess the NAb in people’s blood serum before receiving further COVID vaccine doses.

          Related collections

          Most cited references33

          • Record: found
          • Abstract: found
          • Article: not found

          Mechanisms of SARS-CoV-2 entry into cells

          The unprecedented public health and economic impact of the COVID-19 pandemic caused by infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been met with an equally unprecedented scientific response. Much of this response has focused, appropriately, on the mechanisms of SARS-CoV-2 entry into host cells, and in particular the binding of the spike (S) protein to its receptor, angiotensin-converting enzyme 2 (ACE2), and subsequent membrane fusion. This Review provides the structural and cellular foundations for understanding the multistep SARS-CoV-2 entry process, including S protein synthesis, S protein structure, conformational transitions necessary for association of the S protein with ACE2, engagement of the receptor-binding domain of the S protein with ACE2, proteolytic activation of the S protein, endocytosis and membrane fusion. We define the roles of furin-like proteases, transmembrane protease, serine 2 (TMPRSS2) and cathepsin L in these processes, and delineate the features of ACE2 orthologues in reservoir animal species and S protein adaptations that facilitate efficient human transmission. We also examine the utility of vaccines, antibodies and other potential therapeutics targeting SARS-CoV-2 entry mechanisms. Finally, we present key outstanding questions associated with this critical process. Entry of SARS-CoV-2 into host cells is mediated by the interaction between the viral spike protein and its receptor angiotensin-converting enzyme 2, followed by virus–cell membrane fusion. Worldwide research efforts have provided a detailed understanding of this process at the structural and cellular levels, enabling successful vaccine development for a rapid response to the COVID-19 pandemic.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Establishment and validation of a pseudovirus neutralization assay for SARS-CoV-2

            ABSTRACT Pseudoviruses are useful virological tools because of their safety and versatility, especially for emerging and re-emerging viruses. Due to its high pathogenicity and infectivity and the lack of effective vaccines and therapeutics, live SARS-CoV-2 has to be handled under biosafety level 3 conditions, which has hindered the development of vaccines and therapeutics. Based on a VSV pseudovirus production system, a pseudovirus-based neutralization assay has been developed for evaluating neutralizing antibodies against SARS-CoV-2 in biosafety level 2 facilities. The key parameters for this assay were optimized, including cell types, cell numbers, virus inoculum. When tested against the SARS-CoV-2 pseudovirus, SARS-CoV-2 convalescent patient sera showed high neutralizing potency, which underscore its potential as therapeutics. The limit of detection for this assay was determined as 22.1 and 43.2 for human and mouse serum samples respectively using a panel of 120 negative samples. The cutoff values were set as 30 and 50 for human and mouse serum samples, respectively. This assay showed relatively low coefficient of variations with 15.9% and 16.2% for the intra- and inter-assay analyses respectively. Taken together, we established a robust pseudovirus-based neutralization assay for SARS-CoV-2 and are glad to share pseudoviruses and related protocols with the developers of vaccines or therapeutics to fight against this lethal virus.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Electrochemical biosensors.

              Electrochemical biosensors combine the sensitivity of electroanalytical methods with the inherent bioselectivity of the biological component. The biological component in the sensor recognizes its analyte resulting in a catalytic or binding event that ultimately produces an electrical signal monitored by a transducer that is proportional to analyte concentration. Some of these sensor devices have reached the commercial stage and are routinely used in clinical, environmental, industrial, and agricultural applications. The two classes of electrochemical biosensors, biocatalytic devices and affinity sensors, will be discussed in this critical review to provide an accessible introduction to electrochemical biosensors for any scientist (110 references).
                Bookmark

                Author and article information

                Journal
                Anal Chem
                Anal Chem
                ac
                ancham
                Analytical Chemistry
                American Chemical Society
                0003-2700
                1520-6882
                02 January 2023
                17 January 2023
                : 95
                : 2
                : 836-845
                Affiliations
                []Mechanical Engineering Department, Southern Methodist University , Dallas, Texas75275, United States
                []Electrical and Computer Engineering Department, Southern Methodist University , Dallas, Texas75275, United States
                Author notes
                Author information
                https://orcid.org/0000-0003-0539-4793
                https://orcid.org/0000-0001-9670-0340
                https://orcid.org/0000-0002-8838-5683
                Article
                10.1021/acs.analchem.2c03193
                9843623
                36592029
                2f18e08e-47bf-45e8-ac51-8ec4c9d80672
                © 2023 American Chemical Society

                This article is made available via the PMC Open Access Subset for unrestricted RESEARCH re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.

                History
                : 22 July 2022
                : 20 December 2022
                Categories
                Article
                Custom metadata
                ac2c03193
                ac2c03193

                Analytical chemistry
                Analytical chemistry

                Comments

                Comment on this article