          Abstract

          Background

          An electrical storm due to malignant ventricular tachycardia (VT) is a life-threatening condition that requires catheter ablation (CA). Most VT arrhythmias evolve over time after acute myocardial infarction, coronary artery bypass grafting, or chronic heart failure. Clinically, only radiofrequency ablation can identify and block all arrhythmia origin points. The procedure necessitates continuous VT induction in patients, resulting in hemodynamic instability; therefore, extracorporeal membrane oxygenation (ECMO) support is required. Earlier studies have reported substantial mortality rates; however, our results are significantly more favorable. In this study, we combined the minimally invasive extracorporeal circulation (MiECC) approach with ECMO to preserve an appropriate ECMO flow rate, thus reducing intraoperative left heart afterload. We report 21 cases illustrating the usefulness of modified veno-arterial (VA)-ECMO in this scenario.

          Methods

          Data of 21 patients supported by the modified VA-ECMO system (MiECC approach combined with the ECMO system) during VT CA in the Wuhan Asia Heart Hospital between June 2020 and July 2021 were reviewed retrospectively.

          Results

          Successful ablation was achieved in 20 out of 21 patients (95%). The median time for ECMO implantation was 206 min. Only two patients experienced complications post-treatment. All patients made complete recovery and were discharged. All patients were alive at the 1-year-follow-up.

          Conclusions

          Our modified VA-ECMO system helped restore systemic circulation in patients experiencing an electrical storm, thus achieving greater electrical stability during VT CA. Pre-insertion of VA-ECMO can achieve even better results.

          Related collections

          Most cited references35

          • Record: found
          • Abstract: found
          • Article: not found

          Acute hemodynamic decompensation during catheter ablation of scar-related ventricular tachycardia: incidence, predictors, and impact on mortality.

          The occurrence of periprocedural acute hemodynamic decompensation (AHD) in patients undergoing radiofrequency catheter ablation of scar-related ventricular tachycardia (VT) has not been previously investigated.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Extracorporeal Membrane Oxygenation for Hemodynamic Support of Ventricular Tachycardia Ablation.

            We report the experience in a cohort of consecutive patients receiving extracorporeal membrane oxygenation during catheter ablation of unstable ventricular tachycardia (VT) at our center.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Percutaneous hemodynamic support with Impella 2.5 during scar-related ventricular tachycardia ablation (PERMIT 1).

              Percutaneous left ventricular assist devices (pLVADs) are increasingly being used to facilitate ablation of unstable ventricular tachycardia (VT), but the safety profile and hemodynamic benefits of these devices have not been described in a systematic, prospective manner.
                Bookmark

                Author and article information

                Contributors
                Journal
                Int J Cardiol Heart Vasc
                Int J Cardiol Heart Vasc
                International Journal of Cardiology. Heart & Vasculature
                Elsevier
                2352-9067
                24 October 2023
                December 2023
                24 October 2023
                : 49
                : 101283
                Affiliations
                [a ]Wuhan Asia Heart Hospital, Wuhan, China
                [b ]National Taipei University of Nursing and Health Sciences, Taipei, Taiwan
                Author notes
                [* ]Corresponding author. whyxyyly@ 123456aliyun.com
                Article
                S2352-9067(23)00114-8 101283
                10.1016/j.ijcha.2023.101283
                10613908
                2a03b923-8bfc-45db-84a0-85f70feacd18
                © 2023 The Author(s)

                This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

                History
                : 26 July 2023
                : 8 October 2023
                : 14 October 2023
                Categories
                Original Paper

                extracorporeal membrane oxygenation,malignant ventricular tachycardia,hemodynamic instability,electrical storm,catheter ablation

                Comments

                Comment on this article

                scite_
                0
                0
                0
                0
                Smart Citations
                0
                0
                0
                0
                Citing PublicationsSupportingMentioningContrasting
                View Citations

                See how this article has been cited at scite.ai

                scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

                Similar content56

                Cited by2

                Most referenced authors507